Fast Helical Tomotherapy in a head and neck cancer planning study: is time priceless?

نویسندگان

  • Dirk Van Gestel
  • Geert De Kerf
  • Kristien Wouters
  • Wouter Crijns
  • Jan B. Vermorken
  • Vincent Gregoire
  • Dirk Verellen
چکیده

BACKGROUND The last few years, in radiotherapy there has been a growing focus on speed of treatment delivery (largely driven by economical and commercial interests). This study investigates the influence of treatment time on plan quality for helical tomotherapy (HT), using delivery times with Volumetric Modulated Arc Therapy (VMAT; Rapid Arc [RA]) as reference. METHODS In a previous study, double arc RA (Eclipse) and standard HT plans (TomoHD™) were created for five oropharyngeal cancer patients and reported according to ICRU 83 guidelines. By modifying the beam width from 2.5 to 5.0 cm, elevating the pitch and lowering the modulation factor, "TomoFast" (TF) plans were generated with treatment times equal to RA plans. To quantify the impact of TF's craniocaudal gradient, similar plans were generated on TomoEdge(TM) (TomoEdgeFast;TEF). The homogeneity index (HI), conformity index (CI), mean dose, Dnear-max (D2) and Dnear-min (D98) of the PTVs were analyzed as well as the mean dose, specific critical doses and volumes of 26 organs at risk (OARs). Data were analyzed using repeated measures ANOVA. RESULTS With a mean treatment time of 3.05 min (RA), 2.89 min (TF) and 2.95 min (TEF), PTVtherapeutic coverage was more homogeneous with TF (HI.07;SE.01) and TEF (HI.08;SE.01) compared to RA (HI.10;SE.01), while PTVprophylactic was most homogeneous with RA. Mean doses to parotid glands were comparable for RA, TF, TEF: 25.62, 25.34, 23.09 Gy for contralateral and 32.02, 31.96, 30.01 Gy for ipsilateral glands, respectively. OARs' mean doses varied between different approaches not favoring a particular technique. TF's higher dose to OARs at the cranial-caudal edges of the PTVs and its higher integral dose, both due to the extended cranial-caudal gradient, seems to be solved by the new TomoEdge™ software. However, all these faster techniques lose part of standard TomoHD's OAR sparing capacity CONCLUSION It is possible to treat oropharyngeal cancer patients using HT (TF/TEF) within time-frames observed for RA maintaining comparable target coverage and sparing of OARs. This study indicates that treatment time is not technology specific, rather an operator's decision on balancing efficiency and quality.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of survival rates between patients treated with conventional radiotherapy and helical tomotherapy for head and neck cancer

PURPOSE Compared to conventional radiotherapy (RT), intensity-modulated radiotherapy (IMRT) significantly reduces the rate of treatment-induced late toxicities in head and neck cancer. However, a clear survival benefit of IMRT over conventional RT has not yet been shown. This study is among the first comparative study to compare the survival rates between conventional RT and helical tomotherapy...

متن کامل

Initial clinical experience with helical tomotherapy for head and neck cancer.

BACKGROUND To report a single-institutional experience with the use of helical tomotherapy (HT)-based intensity-modulated radiotherapy (IMRT) for head and neck cancer. METHODS Seventy-seven consecutive patients were treated with HT for squamous cell carcinoma of the head and neck to a median dose of 66 Gy (range, 60 to 72 Gy). Megavoltage CT scans were obtained as part of an image-guided regi...

متن کامل

Fast, simple, and informative patient-specific dose verification method for intensity modulated total marrow irradiation with helical tomotherapy

BACKGROUND Patient-specific dose verification for treatment planning in helical tomotherapy is routinely performed using a homogeneous virtual water cylindrical phantom of 30 cm diameter and 18 cm length (Cheese phantom). Because of this small length, treatment with total marrow irradiation (TMI) requires multiple deliveries of the dose verification procedures to cover a wide range of the targe...

متن کامل

Helical tomotherapy for head and neck squamous cell carcinoma: dosimetric comparison with linear accelerator-based step-and-shoot IMRT.

BACKGROUND Linear Accelerator-based Intensity Modulated Radiation Therapy (IMRT), either as step-and shoot (SS) or in dynamic mode, is now considered routine in the definitive management of head and neck squamous cell carcinoma (HNSCC). Helical TomoTherapy (HT) is a new platform to deliver IMRT. This study aims to compare step-and-shoot Intensity Modulated Radiation Therapy (SS IMRT) with dynam...

متن کامل

Re-irradiation of recurrent head and neck carcinomas: comparison of robust intensity modulated proton therapy treatment plans with helical tomotherapy

BACKGROUND To test the hypothesis that the therapeutic ratio of intensity-modulated photon therapy using helical tomotherapy (HT) for retreatment of head and neck carcinomas can be improved by robust intensity-modulated proton therapy (IMPT). METHODS Comparative dose planning with robust IMPT was performed for 7 patients retreated with HT. RESULTS On average, HT yielded dose gradients steep...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015