[Report based on Fiscal 2010 Diagnostic X-ray Equipment Questionnaire Survey (conditions of X-ray units and similar equipment)].

نویسندگان

  • Nobuhiko Sato
  • Hiroki Saito
  • Tadafumi Miyazono
  • Masaru Takahashi
  • Toru Negishi
  • Yoh Kato
  • Shinji Abe
  • Yoshio Imai
  • Hiroshi Asano
چکیده

On X-ray diagnostic technology, it is important to grasp a change of the X-ray high-voltage equipment and radiographic technique factors. The 1st questionnaire was performed in 1974, and it carried out after that every five years, and conducted 8th investigation. As a result, we requested 656 institutions and got a reply from 103 institutions. The response rate was 15.7%. For X-ray high-voltage equipment, the inverter-type device shifts to 83.6% from 73.4% of last time. X-ray high-voltage equipment will be shifted to inverter-type device the near future. For X-ray tube device, the target angle becomes more smaller than usual, and maximum anode heat content is increasing tendency. The spread of digital devices is being advanced, and especially the flat panel detector (FPD) increases in the devices. The spread of soft copy diagnoses is 73.8% for chest image diagnoses, and 49.5% for breast image diagnosis. For the device management, the ratio of institutions measured at purchase time was 91.2%. But, the ratio of institutions performed an invariability examination was 58.4%. It is required to grasp the performance of an X-ray equipment and peripheral equipment, and to perform accuracy control in order to obtain proper radiographic technique factors and imaging. In order to use it for the improvement in photography technology, we would like to continue to conduct this investigation periodically.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance Evaluation of Diagnostic X-Ray Equipment Regarding the Hospital Size in the Republic of Korea

  Introduction: The Republic of Korea has developed a national standard based on which diagnostic X-ray equipment must be tested every 3 years. Accordingly, the performance of X-ray equipment used in all hospitals is evaluated by national certification bodies in compliance with the safety management regulations for X-ray equipment. However, if the equipment i...

متن کامل

Quality assessment of conventional X-ray diagnostic equipment by measuring X-ray exposure and tube output parameters in Great Khorasan Province, Iran

Introduction: Regular implementation of quality control (QC) program in diagnostic X-ray facilities may affect both image quality and patient radiation dose due to the changes in exposure parameters. Therefore, this study aimed to investigate the status of randomly selected conventional radiographic X-ray devices installed in radiology centers of Great Khorasan Province, Iran, to produce the da...

متن کامل

[Report based on fiscal 2005 diagnostic X-ray equipment questionnaire survey-conditions of radiography-].

In this report, we summarize the survey of diagnostic X-ray equipment conducted in 2005, focusing on exposure conditions. What we would like to point out in this report is how prevalent digital image receptor systems have become, including flat panel detectors (FPD), which did not exist in our last survey five years ago. FPD have become popular very quickly among the digital receptor systems us...

متن کامل

[Report based on fiscal 2005 diagnostic X-ray equipment questionnaire survey-A photography system-].

In accordance with a questionnaire survey of diagnostic X-ray equipment enforced in 2005, this report was focused mainly on a photography device. The paper questionnaire was mailed to 667 institutions, and the collection rate was 20.4%. Introductions of digital photographic devices are progressing and flat panel detectors (FPD) are spreading in addition to computed radiography (CR). Examination...

متن کامل

An Enumeration Survey on Diagnostic X-Ray Generators and Essential Safety Parameters in Mizoram, India

Introduction: Best radiography practice involves operational optimal machine performance, delivering cost-effective healthcare services under appropriate safety conditions for workers and the public. The present study aimed to investigate the safety status of diagnostic X-ray installations in Mizoram, India. Material and Methods: Lineari...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nihon Hoshasen Gijutsu Gakkai zasshi

دوره 70 12  شماره 

صفحات  -

تاریخ انتشار 2014