Adaptive Wide-Area Damping Control Scheme for Smart Grids with Consideration of Signal Time Delay
نویسندگان
چکیده
As an important part of the smart grid, a wide-area measurement system (WAMS) provides the key technical support for power system monitoring, protection and control. But 20 uncertainties in system parameters and signal transmission time delay could worsen the damping effect and deteriorate the system stability. In the presented study, the subspace system identification technique (SIT) is used to firstly derive a low-order linear model of a power system from the measurements. Then, a novel adaptive wide-area damping control scheme for online tuning of the wide-area damping controller (WADC) parameters using the residue method is proposed. In order to eliminate the effects of the time delay to the signal transmission, a simple and practical time delay compensation algorithm is proposed to compensate the time delay in each wide-area control signal. Detailed examples, inspired by the IEEE test system under various disturbance scenarios, have been used to verify the effectiveness of the proposed adaptive wide-area damping control scheme.
منابع مشابه
Design Supplementary Controller Based on Stabilizing Effect of Delay for Damping Inter Area Oscillations in a Power System
The delay associated with signal transmission through the wide-area measurement system reduces the functionality of the power oscillation damping control system. One of the important issues is the poor operation of the supplementary controller against delay existence, which limits the efficiency of damping of ancillary equipment, such as SVCs in a power system. This paper as a solution proposes...
متن کاملAdaptive Setting of UFLS Relay Using Hourly Programming with Consideration of Renewable Energy Sources in Smart Grid
In the light of the emergence of smart grids, the functions associated with this type of grids in the blocks of the energy management system require the adoption of robust strategies in order to provide a higher level of control and protection. Under-frequency load shedding (UFLS) sheds load blocks when the frequency drop is below the threshold limit. In adaptive UFLS, in an advanced telecommun...
متن کاملDelay-Scheduled Controllers for Inter-Area Oscillations Considering Time Delays
Unlike the existing views that was introduced the existence of delay caused by the transmission of wide area measurement system data (WAMS) into the controllers input of the power oscilation damping (POD) by communication networks as a reason for poor performance of the POD controllers. This paper shows that the presence of time delay in the feedback loop may improve the performance of a POD co...
متن کاملA Methodology for Unified Assessment of Physical and Geographical Dependencies of Wide Area Measurement Systems in Smart Grids
Wide Area Measurement Systems (WAMS) enable real time monitoring and control of smart grids by combining digital measurement devices, communication and control systems. As WAMS consist of various infrastructures, they imply complex dependencies among their underlying systems and components of different types, such as cyber, physical and geographical dependencies. Although several works exist in...
متن کاملDamping of Inter-Area Low Frequency Oscillation Using an Adaptive Wide-Area Damping Controller
This paper presents an adaptive wide-area damping controller (WADC) based on generalized predictive control (GPC) and model identification for damping the inter-area low frequency oscillations in large-scale inter-connected power system. A recursive least-squares algorithm (RLSA) with a varying forgetting factor is applied to identify online the reduced-order linearlized model which contains do...
متن کامل