Artisan lens implantation to correct aphakia after vitrectomy for retained nuclear lens fragments.
نویسندگان
چکیده
PURPOSE To report the results of pars plana vitrectomy (PPV) for retained lens fragments with implantation of an Artisan intraocular lens (IOL) (Ophtec) to correct aphakia. SETTING University-based referral center. METHODS In this retrospective case-controlled study, patients who had had a PPV to remove dislocated lens fragments and implantation of an Artisan IOL for pseudophakic correction during initial cataract surgery or PPV were reviewed. RESULTS Thirteen patients were identified. The preoperative visual acuity was better than 20/200 in 5 patients and the intraocular pressure (IOP) was higher than 21 mm Hg in 8 patients; 3 patients had normal corneas. In 4 patients, an Artisan IOL was implanted during cataract surgery. Postoperative complications included recurrent erosion (1 eye), premacular fibrosis (2 eyes), and a retinal tear (1 eye). Elevation of the IOP occurred in 2 patients and was controllable with medication. Pupillary block developed in 1 patient and persistent cystoid macular edema in another. All but 2 patients gained more than 2 lines of visual acuity postoperatively, and all corneas remained clear during the follow-up (mean 28.9 months; range 2.5 to 69.0 months). CONCLUSIONS After the removal of dislocated lens fragments with a PPV, Artisan IOL implantation in aphakic patients without capsule support led to few complications and good visual acuity. Placement of an Artisan IOL requires fewer manipulations than transscleral suture fixation of a posterior chamber IOL.
منابع مشابه
Traumatic aniridia and aphakia after Artisan intraocular lens implantation.
Traumatic aniridia and aphakia occurred in the left eye of a 22-year-old man who had had Artisan (Ophtec) phakic intraocular lens (IOL) implantation. Aniridia was probably the result of the relatively large wound used to implant the nonfoldable IOL. Although the eye had severe traumatic damage, vision was recoverable through a 2-stage procedure of vitrectomy and subsequent scleral suture fixati...
متن کاملCLINICAL SCIENCE Long-Term Follow-Up of the Corneal Endothelium After Artisan Lens Implantation for Unilateral Traumatic and Unilateral Congenital Cataract in Children
Purpose: To retrospectively estimate the long-term corneal endothelial cell loss in children after perforating corneal trauma and implantation of an iris-fixated anterior-chamber intraocular lens (IOL), either the Artisan aphakia lens or the Artificial Iris Implant, and to compare this corneal endothelial cell loss to that in children who received an Artisan aphakia lens to correct aphakia afte...
متن کاملSecondary Artisan-Verysise aphakic lens implantation.
PURPOSE To evaluate efficacy, predictability and safety of Artisan-Verysise intraocular lens (IOL) secondary implantation for aphakia correction. SETTING Instituto de Microcirugía Ocular, and Autonoma University of Barcelona, Barcelona, Spain. METHODS Uncorrected visual acuity, best spectacle-corrected visual acuity (BSCVA), manifest refraction, endothelial cell count, and clinical complica...
متن کاملImplantation of iris-claw Artisan intraocular lens for aphakia in Fuchs’ heterochromic iridocyclitis
Implantation of iris-claw Artisan intraocular lens (IOL) is a surgical option for correction of aphakia; however, these IOLs have not been used in eyes with uveitis including Fuchs' heterochromic iridocyclitis (FHI) due to possible risk of severe postoperative intraocular inflammation. In the case reported here, we secondarily implanted an Artisan IOL in a 28-year-old man with FHI who had aphak...
متن کاملCataract extraction and intraocular lens implantation in children with uveitis.
AIM To evaluate the long term results of cataract surgery with intraocular lens implantation (IOL) in children with uveitis. METHODS The study included 10 eyes in seven children (age 3.5-10 years, mean 6.5 years). The cataract surgery included capsulorhexis of the anterior and the posterior capsule, anterior vitrectomy in some eyes, and implantation of a heparin surface modified (HSM) poly(me...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of cataract and refractive surgery
دوره 30 12 شماره
صفحات -
تاریخ انتشار 2004