Neisseria species identification assay for the confirmation of Neisseria gonorrhoeae-positive results of the COBAS Amplicor PCR.
نویسندگان
چکیده
Screening assays for Neisseria gonorrhoeae exhibit low positive predictive values, particularly in low-prevalence populations. A new real-time PCR assay that detects and identifies individual Neisseria spp. using melt curve analysis was compared to two previously published supplementary assays. NsppID, a 16S rRNA real-time PCR/melt curve assay developed to distinguish N. gonorrhoeae from other Neisseria spp., was compared to real-time PCR assays targeting genes reportedly specific for N. gonorrhoeae, the cppB gene and the porA pseudogene. A total of 408 clinical specimens (324 female endocervical swabs and 84 male urine or urogenital swab specimens) were screened using the COBAS Amplicor assay for Chlamydia trachomatis and N. gonorrhoeae (CT/NG) (Roche Diagnostics, Indianapolis, IN) followed by confirmatory testing via real-time PCR. The NsppID assay detected Neisseria spp. in 150/181 COBAS-positive specimens (82%), including six dual infections, and identified N. gonorrhoeae in 102 (56%) specimens. Sixty-nine of 181 (38%) specimens were positive for N. gonorrhoeae by porA pseudogene, and 115/181 (64%) were positive for cppB. However, cppB was also positive in 15% of COBAS-negative specimens, more than either NsppID (4%) or porA pseudogene (2%) assays. The porA pseudogene assay had the highest specificity for both genders but the lowest sensitivity, especially in female specimens. NsppID had a slightly lower specificity but greater sensitivity and overall accuracy. The least desirable confirmatory assay was cppB, due to poor specificity. The NsppID assay is an accurate confirmatory assay for N. gonorrhoeae detection. In addition, the NsppID assay can identify the non-N. gonorrhoeae species responsible for the majority of false-positive results from the COBAS Amplicor CT/NG assay.
منابع مشابه
Evaluation of real time polymerase chain reaction assays for confirmation of Neisseria gonorrhoeae in clinical samples tested positive in the Roche Cobas Amplicor assay.
OBJECTIVE Development of a rapid, sensitive, and accurate assay for confirmation of Neisseria gonorrhoeae in clinical samples. METHOD Two real time polymerase chain reaction (PCR) assays, developed on the LightCycler for amplification of the N gonorrhoeae cppB gene, were utilised for confirmation of this bacterial pathogen in samples positive by the Roche Cobas Amplicor assay. Performance cha...
متن کاملEvaluation of conventional and real-time PCR assays using two targets for confirmation of results of the COBAS AMPLICOR Chlamydia trachomatis/Neisseria gonorrhoeae test for detection of Neisseria gonorrhoeae in clinical samples.
Two conventional PCR-enzyme immunoassays (PCR-EIAs) and two real-time PCR assays (LightCycler system; Roche Diagnostics) were evaluated as confirmation assays with cppB and 16S rRNA genes as targets. Of 765 male and female genitourinary and nasopharyngeal specimens positive for Neisseria gonorrhoeae in the COBAS AMPLICOR Chlamydia trachomatis/Neisseria gonorrhoeae PCR test (Roche Diagnostics), ...
متن کاملAn assessment of the Roche Amplicor Chlamydia trachomatis/Neisseria gonorrhoeae multiplex PCR assay in routine diagnostic use on a variety of specimen types.
The Roche Cobas Amplicor Chlamydia trachomatis/Neisseria gonorrhoeae polymerase chain reaction (PCR) assay can simultaneously detect both C. trachomatis and N. gonorrhoeae, and has been cleared by United States Food and Drug Administration (FDA) for the testing of endocervical and urethral swabs and urine specimens. The Amplicor N. gonorrhoeae PCR target sequence is known to be present in some ...
متن کاملComparison between the LCx Probe system and the COBAS AMPLICOR system for detection of Chlamydia trachomatis and Neisseria gonorrhoeae infections in patients attending a clinic for treatment of sexually transmitted diseases in Amsterdam, The Netherlands.
Two assays for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae were compared: the LCx Probe system (the LCx system; Abbott Diagnostic Laboratories, North Chicago, Ill.) and the COBAS AMPLICOR C. trachomatis/N. gonorrhoeae system (the COBAS AMPLICOR system; Roche Diagnostic Systems, Branchburg, N.J.). Endocervical swab specimens, male urethral swab specimens, and female and male...
متن کاملValidation of a laboratory-developed real-time PCR protocol for detection of Chlamydia trachomatis and Neisseria gonorrhoeae in urine.
OBJECTIVE To evaluate a sensitive and specific, real-time PCR assay with internal control for Chlamydia trachomatis and Neisseria gonorrhoeae DNA detection in urine specimens. METHODS The diagnostic performance of a laboratory-developed quadruplex assay (LDQA) targeting the cryptic plasmid and MOMP genes of C trachomatis, the porA pseudogene of N gonorrhoeae and a synthetic internal control w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 45 5 شماره
صفحات -
تاریخ انتشار 2007