Lymphocyte propionyl-CoA carboxylase and its activation by biotin are sensitive indicators of marginal biotin deficiency in humans.
نویسندگان
چکیده
BACKGROUND Marginal biotin deficiency may be a human teratogen. A biotin status indicator that is not dependent on renal function may be useful in studies of biotin status during pregnancy. A previous study of experimental biotin deficiency suggested that propionyl-coenzyme A carboxylase (PCC) activity in peripheral blood lymphocytes (PBLs) is a sensitive indicator of biotin status. OBJECTIVE We examined the utility of measuring PCC activity and the activation of PCC by biotin in detecting marginal biotin deficiency. DESIGN Marginal biotin deficiency was induced in 7 adults (3 women) by egg-white feeding for 28 d. Blood and urine were obtained on days 0, 14, and 28 (depletion phase) and 44 and 65 (repletion phase). PBLs were incubated with (activated) or without (control) biotin before PCC assay. The activation coefficient of PCC is the ratio of PCC activity in activated PBLs to that in control PBLs. The significance of differences for all measurements was tested by repeated-measures analysis of variance with Fisher's post hoc test and Bonferroni correction. RESULTS Changes in the urinary excretion of biotin and of 3-hydroxyisovaleric acid confirmed that marginal biotin deficiency was successfully induced. By day 14, PCC activity had decreased (P < 0.0001) to below the lower limit of normal in all subjects. By day 28, the activation coefficient of PCC had increased significantly (P = 0.003) and was above the upper limit of normal in 6 of 7 subjects. CONCLUSION PCC activity is the most sensitive indicator of biotin status tested to date. In future pregnancy studies, the use of lymphocyte PCC activity data should prove valuable in the assessment of biotin status.
منابع مشابه
Marginal biotin deficiency is common in normal human pregnancy and is highly teratogenic in mice.
In studies of marginal biotin deficiency induced experimentally in adults, increased urinary excretion of 3-hydroxyisovaleric acid (3HIA), which likely reflects decreased activity of the biotin-dependent enzyme beta-methylcrotonyl-CoA carboxylase, and decreased activity of the biotin-dependent enzyme propionyl-CoA carboxylase (PCC) in peripheral blood lymphocytes have been validated as indices ...
متن کاملAdequate intake of biotin in pregnancy: why bother?
Frank, symptomatic biotin deficiency is a rare occurrence. The only well-documented cases have occurred in association with total or near total intravenous feeding without biotin supplementation, during chronic consumption of un-denatured egg white, and with inborn errors of metabolism that lead to biotin wasting (1, 2). A single case that does not fit any of these established associations is t...
متن کاملEffects of biotin on pyruvate carboxylase, acetyl-CoA carboxylase, propionyl-CoA carboxylase, and markers for glucose and lipid homeostasis in type 2 diabetic patients and nondiabetic subjects.
BACKGROUND Several studies have shown that biotin affects glucose homeostasis. Serum biotin concentrations are lower in subjects with type 2 diabetes than in control subjects. Lymphocyte propionyl-CoA carboxylase (PCC; EC 6.4.1.3) activity has proved to be a sensitive indicator of biotin status that is more accurate than is serum biotin concentration. OBJECTIVE We studied the activity of PCC,...
متن کاملBiotin deficiency decreases life span and fertility but increases stress resistance in Drosophila melanogaster.
Biotin deficiency is associated with fetal malformations and activation of cell survival pathways in mammals. In this study we determined whether biotin status affects life span, stress resistance, and fertility in the fruit fly Drosophila melanogaster. Male and female flies of the Canton-S strain had free access to diets containing 6.0 (control), 4.8, 2.5, or 0 pmol biotin/100 mg. Biotin conce...
متن کاملThe relationship between plasma biotin concentration and circulating leucocyte beta-methylcrotonyl-CoA carboxylase and propionyl-CoA carboxylase.
1. A newly developed biotin assay was used to monitor plasma and urinary biotin concentration after the oral administration of biotin. 2. In two normal subjects, leucocyte propionyl-CoA carboxylase and beta-methylcrotonyl-CoA carboxylase were markedly stimulated after the administration of biotin.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The American journal of clinical nutrition
دوره 84 2 شماره
صفحات -
تاریخ انتشار 2006