Coronal alignment after total knee replacement.

نویسندگان

  • R S Jeffery
  • R W Morris
  • R A Denham
چکیده

Maquet's line passes from the centre of the femoral head to the centre of the body of the talus. The distance of this line from the centre of the knee on a long-leg radiograph provides the most accurate measure of coronal alignment. Malalignment causes abnormal forces which may lead to loosening after knee replacement. We report a series of 115 Denham knee replacements performed between 1976 and 1981 using the earliest design of components, inserted with intramedullary guide rods. Patients were assessed clinically and long-leg standing radiographs were taken before operation, soon after surgery and up to 12 years later. In two-thirds of the knees (68%) Maquet's line passed through the middle third of the prosthesis on postoperative films and the incidence of subsequent loosening was 3%. When Maquet's line was medial or lateral to this, an error of approximately +/- 3 degrees, the incidence of loosening at a median period of eight years was 24%. This difference is highly significant (p = 0.001). Accurate coronal alignment appears to be an important factor in prevention of loosening. Means of improving the accuracy of alignment and of measuring it on long-leg radiographs are discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Coronal alignment after total knee arthroplasty

Recent studies have challenged the long-held notion that neutral mechanical alignment after total knee arthroplasty leads to optimal function and survivorship.The ideal alignment for function and survivorship may actually be different.Kinematic alignment, where components are implanted to re-create the natural flexion/extension axis of the knee, may lead to improved functional results.Residual ...

متن کامل

Do we need hip-ankle radiographs to assess the coronal alignment and implant position after total knee replacement?

This open-access article is published and distributed under the Creative Commons Attribution NonCommercial No Derivatives License (http://creativecommons.org/licenses/by-nc-nd/3.0/), which permits the noncommercial use, distribution, and reproduction of the article in any medium, provided the original author and source are credited. You may not alter, transform, or build upon this article witho...

متن کامل

Review article: Patient-specific versus standard instrumentation for total knee arthroplasty.

This meta-analysis reviewed 12 studies comparing patient-specific instrumentation (PSI) with standard instrumentation (SI) for total knee arthroplasty in terms of postoperative coronal alignment and operation time. There is no significant difference between PSI and SI in terms of hip-knee-ankle angle (overall coronal alignment or mechanical axis), tibial coronal alignment, and operation time.

متن کامل

An analysis of intra-operative variation in femorotibial alignment in the coronal plane during computer navigated total knee replacement.

A prospective study was performed to assess the intra-operative variation in femoral and tibial axis alignment during navigated total knee replacement. The intra-operative initial, trial and final mechanical axis alignments were recorded from the navigation system. The mean variation and correlation coefficient were calculated and analysed. There were 40 patients (24 females, 16 males), with ag...

متن کامل

Comparison of robot-assisted and conventional total knee arthroplasty: a controlled cadaver study using multiparameter quantitative three-dimensional CT assessment of alignment.

INTRODUCTION A functional total knee replacement has to be well aligned, which implies that it should lie along the mechanical axis and in the correct axial and rotational planes. Incorrect alignment will lead to abnormal wear, early mechanical loosening, and patellofemoral problems. There has been increased interest of late in total knee arthroplasty with robotic assistance. This study was con...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 73 5  شماره 

صفحات  -

تاریخ انتشار 1991