چکیده

UNLABELLED PURPOSE. To compare the inner contour of the femoral component of 10 total knee replacement (TKR) designs for possible exchange in use. METHODS Inner contours of the femoral components of 10 cemented, cruciate-retaining TKR designs (e.motion, Genesis, Genia, Innex, LCS, Multigen Plus, NexGen, PFC, Scorpio, Vanguard) were scanned and reconstructed to 2-dimensional contours. Their cross-sections were compared by superimposition and aligning at the distal and anterior cuts. The patellar notch and outer contour were not analysed. RESULTS The maximum deviation was 5 mm in the posterior and posterior oblique cuts and 10 mm in the anterior oblique cut. Based on similarity of the inner contour, LCS and Innex was classified as group I, e.motion, Genesis, Scorpio, Vanguard, and Multigen Plus as group II, and Genia, NexGen, and PFC as group III. All 2 designs in group I were not compatible with the other 8 designs. Four of the 5 designs in group II showed good compatibility. All 3 designs in group III significantly differed in the posterior and oblique cuts. CONCLUSION A standardised inner contour of the femoral component can increase compatibility of different TKR systems in revision surgery and reduces the extent of bone resection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Distal Femoral Valgus Cut Errors in Total Knee Replacement

The causes of malalignment in total knee arthroplasty can be categorized into three different groups; 1) Errors in bone cuts 2) Errors in implant fixations, and 3) The method of setting down the cutting guides (1). We would like to announce that more several distal femoral valgus cut errors may occur during total knee replacement.

متن کامل

Hybrid total knee arthroplasty: 10- to 16-year follow-up.

A cementless femoral component may allow for a smaller surgical incision when a minimally invasive approach is used during primary total knee arthroplasty. Fixation by cement is the gold standard for total knee arthroplasty. The results of cementless total knee arthroplasty are mixed. Cementless femoral components have done well. Although some tibial components have performed well at long-term ...

متن کامل

Differences between native and prosthetic knees in terms of cross-sectional morphology of the femoral trochlea: a study based on three-dimensional models and virtual total knee arthroplasty

BACKGROUND The cross-sectional morphology of the prosthetic knee is crucial to understanding patellar motion and quadriceps strength after total knee arthroplasty. However, few comparative evaluations of the cross-sectional morphology of the femoral trochlea have been performed in the native knee and currently available femoral implants, and the relationship between the trochlear anatomy of pro...

متن کامل

Medial Unicompartmental Osteoarthritis (MUO) of the Knee: Unicompartmental Knee Replacement (UKR) or Total Knee Replacement (TKR)

The aim of this review article is to analyze the clinical effectiveness of total knee replacement (TKR) compared to unicompartmental knee replacement (UKR) in patients with medial unicompartmental osteoarthritis (MUO) in terms of survival rates, revision rates and postoperative complications. The search engine was MedLine. The keywords used were: medial knee osteoarthritis. Three thousand and n...

متن کامل

Flexion and extension gap balancing in revision total knee arthroplasty.

UNLABELLED Revision total knee arthroplasty presents a unique set of problems when attempting to balance flexion and extension gaps. Loss of soft tissue support and established deformity can make balancing difficult. One needs to balance the flexion and extension gap heights as well as medial and lateral symmetry, which may not always be attainable. We used a set of stepwise techniques to reest...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic surgery

دوره 20 1  شماره 

صفحات  -

تاریخ انتشار 2012