Flow injection amperometric determination of persulfate in cosmetic products using a Prussian Blue film-modified electrode
نویسندگان
چکیده
A flow-injection system with a glassy carbon disk electrode modified with Prussian Blue film is proposed for the determination of persulfate in commercial samples of hair bleaching boosters by amperometry. The detection was obtained by chronoamperometric technique and the sample is injected into the electrochemical cell in a wall jet configuration. Potassium chloride at concentration of 0.1 mol L acted as sample carrier at a flow rate of 4.0 mL min and supporting-electrolyte. For 0.025 V (vs. Ag/AgCl) applied voltage, the proposed system handles ca. 160 samples per hour (1.0 10 1.0 10 mol L of persulfate), consuming about 200 μL sample and 11 mg KCl per determination. Typical linear correlations between electrocatalytic current and persulfate concentration was ca. 0.9998. The detection limit is 9.0 10 mol L and the calculated amperometric sensibility 3.6 10 μA L mol. Relative standard deviation (n =12) of a 1.0 10 mol L sample is about 2.2%. The method was applied to persulfate determination in commercial hair-bleaching samples and results are in agreement with those obtained by titrimetry at 95% confidence level and good recoveries (95 112%) of spiked samples were found.
منابع مشابه
Flow-Injection Amperometric Determination of Ascorbic Acid Using a Graphite-Epoxy Composite Electrode Modified with Cobalt Phthalocyanine
A flow injection method is reported for the determination of ascorbic acid based on amperometric detection, using a cobalt(II) phthalocyanine (CoPc) modified graphite-epoxy electrode. The amperometric respons was evaluated with regard to pH, ionic strength of the electrolyte, flow rate of the carrier solution, injected sample volume and conditioning time of the electrode. The limit of detec...
متن کاملElectrocatalytic oxidation of sulfite Ion at the surface carbon ceramic modified electrode with prussian blue
The redox properties of sulfite ion has been examind using cyclic voltammetry in acetonitrile solvent at the surface of gold, pelatin and glassy carbon electrodes. It has bben found tha, sulfite ion exhibits two electron oxidation peak with EC’ mechanism. A novel chemically modified electrode containing Prussian blue complex and multi wall carbon nanotubes (MWCNs) was achieved on the surface of...
متن کاملApplication of carbon ceramic modified electrode with prussian blue for electrocatalytic oxidation of nitrite ion
A novel chemically modified electrode containing Prussian blue complex was achieved on the surface of glass carbon electrode by sol-gel technique. The electrochemical behavior of modified electrode was characterized by cyclic voltammetry in detail. The film electrode obtained was very stable and exhibited electrocatalytic response for oxidation of nitrite. Results showed at bare GC electrode, a...
متن کاملVoltammetric Behavior and Amperometric Determination of Ascorbic Acid at Cadmium Pentacyanonitrosylferrate Film Modified GC Electrode
The present work, describes electrochemical preparation of a novel cadmium pentacyanonitrosylferrate (CdPCNF) film as a Prussian Blue analogous on the glassy carbon (GC) electrode from a solution of 5 mM CdCl2 and 5 mM Na2[Fe(CN)5NO]. The effect of experimental conditions such as pH and composition of electrodeposition solution on the peak current of the modified electrode and its stability wer...
متن کاملGlucose Biosensor Based on Chitosan-Gold and Prussian Blue-Gold Nanoparticles
Amperometric glucose biosensors were constructed by codeposition of glucose oxidase (GOx) with chitosangold (chitosan-AuNP) on gold-Prussian Blue (Au-PB) nanoparticles modified glassy carbon electrodes (GCE). The high stability of the biosensors was achieved using electrochemically controllable in situ Au-PB film preparation following the film covering with GOx layer encrusted with chitosan-AuN...
متن کامل