Finite element modeling of the contact interface between trans-tibial residual limb and prosthetic socket.
نویسندگان
چکیده
Finite element method has been identified as a useful tool to understand the load transfer mechanics between a residual limb and its prosthetic socket. This paper proposed a new practical approach in modeling the contact interface with consideration of the friction/slip conditions and pre-stresses applied on the limb within a rectified socket. The residual limb and socket were modeled as two separate structures and their interactions were simulated using automated contact methods. Some regions of the limb penetrated into the socket because of socket modification. In the first step of the simulation, the penetrated limb surface was moved onto the inner surface of the socket and the pre-stresses were predicted. In the subsequent loading step, pre-stresses were kept and loadings were applied at the knee joint to simulate the loading during the stance phase of gait. Comparisons were made between the model using the proposed approach and the model having an assumption that the shape of the limb and the socket were the same which ignored pre-stress. It was found that peak normal and shear stresses over the regions where socket undercuts were made reduced and the stress values over other regions raised in the model having the simplifying assumption.
منابع مشابه
Parametric analysis using the finite element method to investigate prosthetic interface stresses for persons with trans-tibial amputation.
A finite element (FE) model of the below-knee residual limb and prosthetic socket was created to investigate the effects of parameter variations on the interface stress distribution during static stance. This model was based upon geometric approximations of anthropometric residual limb geometry. The model was not specific to an individual with amputation, but could be scaled to approximate the ...
متن کاملInternal mechanical conditions in the soft tissues of a residual limb of a trans-tibial amputee.
Most trans-tibial amputation (TTA) patients use a prosthesis to retain upright mobility capabilities. Unfortunately, interaction between the residual limb and the prosthetic socket causes elevated internal strains and stresses in the muscle and fat tissues in the residual limb, which may lead to deep tissue injury (DTI) and other complications. Presently, there is paucity of information on the ...
متن کاملParametric analysis using the finite element method to investigate prosthetic interface stresses for persons with below-knee amputation
A finite element (FE) model of the below-knee residual limb and prosthetic socket was created to investigate the effects of parameter variations on the interface stress distribution during static stance . This model was based upon geometric approximations of anthropometric residual limb geometry . The model was not specific to an individual with amputation, but could be scaled to approximate th...
متن کاملGeneric, geometric finite element analysis of the transtibial residual limb and prosthetic socket.
Finite element (FE) analysis was used to investigate the stress distribution between the residual limb and prosthetic socket of persons with transtibial amputation (TTA). The purpose of this study was to develop a tool to provide a quantitative estimate of prosthetic interface pressures to improve our understanding of residual limb/prosthetic socket biomechanics and prosthetic fit. FE models of...
متن کاملClinical Evaluation of Prosthetic Sockets Manufactured By Selective Laser Sintering
A pilot study was undertaken to evaluate the clinical acceptance of prosthetic limb sockets manufactured using solid freeform fabrication (SFF). The fabrication of sockets for amputees is a natural application for SFF. The socket is the part of the prosthetic limb that fits onto the amputee’s residual limb. Each socket is custom manufactured for each individual amputee. Four amputees were succe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical engineering & physics
دوره 26 8 شماره
صفحات -
تاریخ انتشار 2004