Spectral Deconvolution for Gas Chromatography Mass Spectrometry-Based Metabolomics: Current Status and Future Perspectives
نویسندگان
چکیده
Mass spectrometry coupled to gas chromatography (GC-MS) has been widely applied in the field of metabolomics. Success of this application has benefited greatly from computational workflows that process the complex raw mass spectrometry data and extract the qualitative and quantitative information of metabolites. Among the computational algorithms within a workflow, deconvolution is critical since it reconstructs a pure mass spectrum for each component that the mass spectrometer observes. Based on the pure spectrum, the corresponding component can be eventually identified and quantified. Deconvolution is challenging due to the existence of co-elution. In this review, we focus on progress that has been made in the development of deconvolution algorithms and provide thoughts on future developments that will expand the application of GC-MS in metabolomics.
منابع مشابه
Monolithic silica-based capillary reversed-phase liquid chromatography/electrospray mass spectrometry for plant metabolomics.
Application of C18 monolithic silica capillary columns in HPLC coupled to ion trap mass spectrometry detection was studied for probing the metabolome of the model plant Arabidopsis thaliana. It could be shown that the use of a long capillary column is an easy and effective approach to reduce ionization suppression by enhanced chromatographic resolution. Several hundred peaks could be detected u...
متن کاملAutomated resolution of chromatographic signals by independent component analysis-orthogonal signal deconvolution in comprehensive gas chromatography/mass spectrometry-based metabolomics
Comprehensive gas chromatography-mass spectrometry (GC×GC-MS) provides a different perspective in metabolomics profiling of samples. However, algorithms for GC×GC-MS data processing are needed in order to automatically process the data and extract the purest information about the compounds appearing in complex biological samples. This study shows the capability of independent component analysis...
متن کاملComparative Analysis of Mass Spectral Similarity Measures on Peak Alignment for Comprehensive Two-Dimensional Gas Chromatography Mass Spectrometry
Peak alignment is a critical procedure in mass spectrometry-based biomarker discovery in metabolomics. One of peak alignment approaches to comprehensive two-dimensional gas chromatography mass spectrometry (GC×GC-MS) data is peak matching-based alignment. A key to the peak matching-based alignment is the calculation of mass spectral similarity scores. Various mass spectral similarity measures h...
متن کاملCurrent and Future Perspectives on the Structural Identification of Small Molecules in Biological Systems
Although significant advances have been made in recent years, the structural elucidation of small molecules continues to remain a challenging issue for metabolite profiling. Many metabolomic studies feature unknown compounds; sometimes even in the list of features identified as "statistically significant" in the study. Such metabolic "dark matter" means that much of the potential information co...
متن کاملAnalysis of gin essential oil mixtures by multidimensional and one-dimensional gas chromatography/mass spectrometry with spectral deconvolution.
The composition of essential oils and their mixtures used to formulate gin is usually too complex to separate all sample components by standard capillary gas chromatography (GC). In particular, minor constituents that possess important organoleptic properties can be masked by co-elution with major sample components. A solution is provided that combines gas chromatography/mass spectrometry (GC/M...
متن کامل