Harmonic scalpel versus flexible CO2 laser for tongue resection: A histopathological analysis of thermal damage in human cadavers

نویسندگان

  • Duncan F Hanby
  • Grayson Gremillion
  • Arthur W Zieske
  • Bridget Loehn
  • Richard Whitworth
  • Tamir Wolf
  • Anagha C Kakade
  • Rohan R Walvekar
چکیده

BACKGROUND Monopolar cautery is the most commonly used surgical cutting and hemostatic tool for head and neck surgery. There are newer technologies that are being utilized with the goal of precise cutting, decreasing blood loss, reducing thermal damage, and allowing faster wound healing. Our study compares thermal damage caused by Harmonic scalpel and CO2 laser to cadaveric tongue. METHODS Two fresh human cadaver heads were enrolled for the study. Oral tongue was exposed and incisions were made in the tongue akin to a tongue tumor resection using the harmonic scalpel and flexible C02 laser fiber at various settings recommended for surgery. The margins of resection were sampled, labeled, and sent for pathological analysis to assess depth of thermal damage calculated in millimeters. The pathologist was blinded to the surgical tool used. Control tongue tissue was also sent for comparison as a baseline for comparison. RESULTS Three tongue samples were studied to assess depth of thermal damage by harmonic scalpel. The mean depth of thermal damage was 0.69 (range, 0.51 - 0.82). Five tongue samples were studied to assess depth of thermal damage by CO2 laser. The mean depth of thermal damage was 0.3 (range, 0.22 to 0.43). As expected, control samples showed 0 mm of thermal damage. There was a statistically significant difference between the depth of thermal injury to tongue resection margins by harmonic scalpel as compared to CO2 laser, (p = 0.003). CONCLUSION In a cadaveric model, flexible CO2 laser fiber causes less depth of thermal damage when compared with harmonic scalpel at settings utilized in our study. However, the relevance of this information in terms of wound healing, hemostasis, safety, cost-effectiveness, and surgical outcomes needs to be further studied in clinical settings.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Histological Ex Vivo Evaluation of Peri-Incisional Thermal Effect Created by a New-Generation CO2 Superpulsed Laser

The purpose of this study is the evaluation of the histological effects of a new-generation superpulsed CO2 laser through an "ex vivo" study. A CO2 ( λ = 10,600 nm) ultra-speed laser (SmartUS20D, DEKA, Florence, Italy) has been used at different parameters from 2 to 4 watt in Continuous Wave (CW) and Pulsed Wave (PW, 50 Hz) to obtain 30 samples from pig cadaver tongues. All the specimens have b...

متن کامل

In vitro histological evaluation of the surgical margins made by different laser wavelengths in tongue tissues

BACKGROUND Lasers have become standard tools for the surgical treatment of oral lesions. The purpose of this study is to determine the surgical margins and histologically evaluate the tissue thermal effects induced by different types of surgical instruments. MATERIAL AND METHODS Cuts were made in pork tongues' mucosa with different lasers (Er:YAG at 2W with and without air / water spray and a...

متن کامل

Treatment of Rhinophyma with CO2 Laser

Rhinophyma is a benign and disfiguring tumor of the nose, affecting white old men. It represents the end stage of acne rosacea. Hypertrophy of the sebaceous apparatus and fibrosis lead to an enlarged, erythematous nasal tip with comedones. Treatment modalities include Isotretinoin (Which is not effective on severe rhinophyma), freehand scalpel shave, cryosurgery, electrocautery, dermabras...

متن کامل

Treatment of oral mucocele-scalpel versus CO2 laser.

OBJECTIVE To compare the results obtained after oral mucocele resection with the scalpel versus the CO2 laser, based on the complications and recurrences after surgery. PATIENTS AND METHODS Of the 68 patients we studied who have mucocele, 38 were resected with a scalpel and the remaining 30 with the CO2 laser (5-7 W). Patient sex and age were documented, along with location of the lesion as w...

متن کامل

The comparison of thermal tissue injuries caused by ultrasonic scalpel and electrocautery use in rabbit tongue tissue.

The aim of this study compares to the increase in tissue temperature and the thermal histological effects of ultrasonic scalpel, bipolar and unipolar electrosurgery incisions in the tongue tissue of rabbits. This study evaluates the histopathological changes related to thermal change and the maximum temperature values in the peripheral tissue brought about by the incisions carried out by the th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2011