Intense focused ultrasound preferentially stimulates subcutaneous and focal neuropathic tissue: preliminary results.

نویسندگان

  • Abbi M McClintic
  • Trevor C Dickey
  • Michael Gofeld
  • Michel Kliot
  • John D Loeser
  • Philippe Richebe
  • Pierre D Mourad
چکیده

OBJECTIVE Potential peripheral sources of pain from subcutaneous tissue can require invasive evocative tests for their localization and assessment. Here, we describe studies whose ultimate goal is development of a noninvasive evocative test for subcutaneous, painful tissue. DESIGN We used a rat model of a focal and subcutaneous neuroma to test the hypothesis that intense focused ultrasound can differentiate focal and subcutaneous neuropathic tissue from control tissue. To do so, we first applied intense focused ultrasound (2 MHz, with individual pulses of 0.1 second in duration) to the rat's neuroma while the rat was under light anesthesia. We started with low values of intensity, which we increased until intense focused ultrasound stimulation caused the rat to reliably flick its paw. We then applied that same intense focused ultrasound protocol to control tissue away from the neuroma and assayed for the rat's response to that stimulation. RESULTS Intense focused ultrasound of sufficient strength (I(SATA) of 600 +/- 160 W/cm(2) ) applied to the neuroma caused the rat to flick its paw, while the same intense focused ultrasound applied millimeters to a centimeter away failed to induce a paw flick. CONCLUSION Successful stimulation of the neuroma by intense focused ultrasound required colocalization of the neuroma and intense focused ultrasound supporting our hypothesis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intense focused ultrasound stimulation can safely stimulate inflamed subcutaneous tissue and assess allodynia

BACKGROUND Potential peripheral sources of deep pain can require invasive evocative tests for their assessment. Here we perform research whose ultimate goal is development of a non-invasive evocative test for deep painful tissue. METHODS We used a rat model of inflammation to show that intense focused ultrasound (iFU) differentially stimulates inflamed versus control tissue and can identify a...

متن کامل

Numerical Study for Optimizing Parameters of High-Intensity Focused Ultrasound-Induced Thermal Field during Liver Tumor Ablation: HIFU Simulator

Introduction High intensity focused ultrasound (HIFU) is considered a noninvasive and effective technique for tumor ablation. Frequency and acoustic power are the most effective parameters for temperature distribution and the extent of tissue damage. The aim of this study was to optimize the operating transducer parameters such as frequency and input power in order to acquire suitable temperatu...

متن کامل

Intense focused ultrasound: evaluation of a new treatment modality for precise microcoagulation within the skin.

BACKGROUND AND OBJECTIVE Focused ultrasound can produce thermal and/or mechanical effects deep within tissue. We investigated the capability of intense focused ultrasound to induce precise and predictable subepidermal thermal damage in human skin. MATERIALS AND METHODS Postmortem human skin samples were exposed to a range of focused ultrasound pulses, using a prototype device (Ulthera Inc.) e...

متن کامل

Clinical pilot study of intense ultrasound therapy to deep dermal facial skin and subcutaneous tissues.

OBJECTIVE To evaluate the clinical safety of intense ultrasound in the treatment of the dermis and subcutaneous tissues of the face and neck in terms of skin inflammation, pain, adverse events, and histologic features. DESIGN In an open-label, phase 1 study, patients scheduled to undergo a rhytidectomy were enrolled into immediate (face-lift surgery within 24 hours of intense ultrasound treat...

متن کامل

A New Method for the Generation and Use of Focused Ultrasound in Experimental Biology

1. An efficient generator of focused ultrasound has been designed, built, and successfully operated. 2. The generator has been used to produce focal heating in the centers of paraffin blocks, and in a similar manner, focal areas of destruction were obtained deep in fresh liver tissue with minimal effects at the surface and no effects on the intervening tissue. 3. In animals, focused ultrasound ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Pain medicine

دوره 14 1  شماره 

صفحات  -

تاریخ انتشار 2013