Nonvisualization by aortography of patent ductus arteriosus associated with a large proximal left-to-right shunt.
نویسندگان
چکیده
Three cases are presented in which aortography failed to demonstrate the presence of a moderate-sized patent ductus arteriosus in association with a large proximal left to right shunt, but without other circumstances which would tend to diminish left to right shunt flow through the ductus. The ductus was not clinically apparent in any of these cases. Failure of expression of the distal lesion is most readily explained on hemodynamic grounds. A ductus was easily demonstrated in a fourth, otherwise similar, case. it is concluded that variability of expression makes it riaiy to exclude the possibility of a patent ductus arteriosus on the basis of a negative aortogram in the presence of a large proximal left to right shunt. It is possible that aorta-pulmonary artery indicator dilution curves would demonstrate the distal communication.
منابع مشابه
A Simplified Technic for the Detection of Patent Ductus Arteriosus and of Other Left-to-Right Shunts Originating from the Aorta
THE PRESENCE of an isolated patent ductus arteriosus can generally be determined by clinical examination. However, the differentiation of patent ductus arteriosus from the more unusual left-to-right shunts originating from the aorta is notoriously difficult, and in the presence of an associated intracardiac shunt the recognition of a patent ductus arteriosus may not be possible even by means of...
متن کاملDescending aortography with balloon inflation. A technique for evaluating the size of persistent ductus arteriosus in infants with large proximal left to right shunts.
Six infants underwent angiography of the aortic root and the descending aorta with balloon inflation during diagnostic cardiac catheterisation and angiography. In these infants with large proximal left to right shunts, descending aortography with balloon inflation resulted in better opacification of the persistent ductus arteriosus than aortic root angiography, thereby enabling accurate measure...
متن کاملLeft-Sided Patent Ductus Arteriosus
W HEN there is a right-sided aortic arch, persistence of a left-sided ductus arteriosus can readily be demonstrated by angiocardiography. This is important because in some types of eyanotic congenital heart disease, such as in the tetralogy of Fallot, anl artificial aortico-pulmonary (Blalock-Taussig' or Pott S2 shunt) is often created in order to alleviate the distress produced by anoxia. Two ...
متن کاملAberrant right subclavian artery and right-sided ductus arteriosus.
DESCRIPTION A premature newborn weighing 1.9 kg, presenting with cyanosis, feeding and respiratory difficulties was admitted to our centre for further evaluation. An initial echocardiogram suggested a pulmonary atresia with a malalignment infundibular ventricle septum defect with atypical right-sided ductus arteriosus (2.4 mm) arising from the aberrant right subclavian artery (4 mm), which was ...
متن کاملEstimation of the size of the patent ductus arteriosus from hemodynamic data.
The effects of patent ductus arteriosus upon the circulation were studied by Eppinger, Burwell, and Gross (1). Later, Dexter, Haynes, Burwell, Eppinger, Sosman, and Evans (2) described preoperative and postoperative hemodynamic studies obtained by cardiac catheterization in a patient with patent ductus arteriosus. Since the presence of a patent ductus arteriosus can. be detected by physical exa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chest
دوره 60 2 شماره
صفحات -
تاریخ انتشار 1971