Prevention of vertebral body–splitting fractures after multilevel ProDisc-L implantation

نویسندگان

  • Humbert G. Sullivan
  • Rudolf Bertagnoli
  • Mark A. Nigogosyan
  • Nicholas R. Ladwig
  • Hayley L. Born
  • Molly M. Cerniglia
  • Hartmann Habbicht
  • Michelle A. Mathiason
  • Vicki L. McHugh
چکیده

BACKGROUND Prior studies of multilevel ProDisc-L (PD-L) implants (Synthes Spine, Inc., West Chester, Pennsylvania) using the standard US technique have used conventional radiography postoperatively. We found vertebral body-splitting fractures (VB-SFs) in interposed vertebral bodies after 5 sequential multilevel PD-L device implantations using the standard US technique. These were identified with postoperative computed tomography (CT) but were not visible on plain radiographs. In an additional patient, we found that a stress-relieving, pilot holes-only technique did not prevent VB-SFs. The 5 patients operated on with the standard technique composed the background series against which we compared the incidence of VB-SFs in patients operated on with a modification of the standard US technique-a combination of stress-relieving pilot holes, removal of cortex in the chisel path, and a fenestrated chisel (PH/CR/FC)-intended to reduce the incidence of VB-SFs in multilevel PD-L constructs. METHODS Patients receiving multilevel PD-L implants at 2 sites-1 in the United States and the other in Germany-were operated on with the PH/CR/FC technique and their postoperative CT scans evaluated for the presence of VB-SFs. The frequency of VB-SFs in these patients was compared with that of the 5 patients from the background series who were operated on by the standard US technique. The groups' mean sex, age, body mass index, and vertebral body height, as well as average spinal T score, were also compared. RESULTS No fractures were found in 13 interposed vertebral bodies in 11 patients operated on with the PH/CR/FC technique, as compared with 4 VB-SFs and 1 anterior keel cut-to-anterior keel cut fracture in 5 interposed vertebral bodies in 5 patients operated on with the US technique (P ≤ .001). Although the sample sizes were small, this difference in fracture rate was not associated with sex, age, body mass index, or average spinal T score. At up to 13 months of follow-up of patients in the background series, we found that VB-SFs tend not to bridge with bone, instead forming sclerotic margins. CONCLUSIONS The PH/CR/FC technique studied reduced the incidence of VB-SF in multilevel PD-L implants. Because previously published multilevel studies did not use postoperative CT scans and because VB-SFs are not visible on conventional radiography, the incidence of VB-SFs in multilevel PD-L applications may be higher than previously reported. Our findings may contribute to prevention of complications in total disc replacement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Facet joint contact pressure is not significantly affected by ProDisc cervical disc arthroplasty in sagittal bending: a single-level cadaveric study.

BACKGROUND CONTEXT Total disc arthroplasty is a motion-preserving spinal procedure that has been investigated for its impact on spinal motions and adjacent-level degeneration. However, the effects of disc arthroplasty on facet joint biomechanics remain undefined despite the critical role of these posterior elements on guiding and limiting spinal motion. PURPOSE The goal was to measure the pre...

متن کامل

Posterior internal fixation plus vertebral bone implantation under navigational aid for thoracolumbar fracture treatment

The aim of this study was to investigate the method of posterior thoracolumbar vertebral pedicle screw reduction and fixation combined with vertebral bone implantation via the affected vertebral body under navigational aid for the treatment of thoracolumbar fractures. The efficacy of the procedure was also measured. Between June 2005 and March 2011, posterior thoracolumbar vertebral pedicle scr...

متن کامل

Total disc replacement positioning affects facet contact forces and vertebral body strains.

STUDY DESIGN A validated nonlinear three-dimensional finite element (FE) model of a single lumbar motion segment (L3-L4) was used to evaluate the effects of total disc replacement (TDR). The model was implanted with a fixed-bearing TDR (ProDisc-L) at 2 surgically relevant positions and exercised about the 3 anatomic axes. Facet forces, range of motion (RoM), and vertebral body strains were eval...

متن کامل

Experimental Model of Proximal Junctional Fracture after Multilevel Posterior Spinal Instrumentation

There is a high risk of proximal junctional fractures (PJF) with multilevel spinal instrumentation, especially in the osteoporotic spine. This problem is associated with significant morbidity and possibly the need for reoperation. Various techniques have been proposed in an attempt to decrease the risk of PJF but there is no experimental model described for in vitro production of PJF after mult...

متن کامل

Prophylactic vertebroplasty procedure applied with a resorbable bone cement can decrease the fracture risk of sandwich vertebrae: long-term evaluation of clinical outcomes

A sandwich vertebra is formed after multiple osteoporotic vertebral fractures treated by percutaneous vertebroplasty, which has a risk of developing new fractures. The purpose of our study was to (i) investigate the occurrence of new fractures in sandwich vertebra after cement augmentation procedures and to (ii) evaluate the clinical outcomes after prophylactic vertebral reinforcement applied w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2012