Margin evaluation of translational and rotational set-up errors in intensity modulated radiotherapy for cervical cancer.
نویسندگان
چکیده
A clinical target volume (CTV) to planning target volume (PTV) margin recipes was routinely used to ensure dose was actually delivered to target for all (most) patients. Currently used margin recipes were associated with only translational set-up errors in radiotherapy. However, when set-up errors extended to six-degree (6D) scope (three translational and three rotational set-up errors), margin recipe should be re-evaluated. The purpose of this study was to investigate dosimetric changes of targets (both CTV and PTV) coverage when 6D set-up errors were introduced and testify the practicability of currently used margin recipe in radiotherapy. A total number of 105 cone beam computer tomography scans for ten patients with cervical cancer were derived prior to treatment delivery and 6D set-up errors were acquired with image registration tools. Target coverage was evaluated retrospectively for 6D set-up errors introduced plan with 6 mm CTV to PTV margin. Target coverage of PTV showed significant decreases (3.3 %) in set-up errors introduced plans compared with original plans. But CTV coverage was not susceptible to these set-up errors. A tendency of coverage decrease for PTV along with distance away from treatment was testified, from -0.2 to -6.2 %. However, CTV seems changed less, from -0.2 to -0.8 %. The result indicate that a CTV to PTV margin of 6 mm was sufficient to take into account 6D set-up errors for most patients with cervical cancer. Future research suggests a smaller margin to further improve both tumor coverage and organs at risk sparing.
منابع مشابه
Dosimetry evaluation of salivary glands in 3D conformal radiotherapy and intensity modulated radiotherapy in oral tongue cancer
Introduction: The purpose of this study was to evaluate the dosimetric and radiobiological parameters of salivary glands in treatment of patients with oral tongue cancer by 3D conventional radiotherapy (3D-CRT) and intensity modulated radiation therapy (IMRT) techniques. Materials and Methods: This study was performed on treatment planning of patients with oral tongue cancer in T2-3/N0 cancer s...
متن کاملComparison of set up accuracy among three common immobilisation systems for intensity modulated radiotherapy of nasopharyngeal carcinoma patients
INTRODUCTION In intensity modulated radiotherapy (IMRT) of nasopharyngeal carcinoma (NPC) patients, an effective immobilisation system is important to minimise set up deviation. This study evaluated the effectiveness of three immobilisation systems by assessing their set up deviations. METHODS Patients were randomly assigned to one of the three immobilisation systems: (1) supine on head rest ...
متن کاملSurgeons’ Errors in the Management of Patients with Cervical Cancer
Background and Aim: Generally, in patients with cervical cancer, careful preliminary evaluation is necessary for avoiding improper surgical procedures and making effective clinical decisions for treatment. The aim of this study was to determine surgeons’ errors, which necessitate a combination of surgery and radiotherapy for cervical cancer patients. Methods: In this retrospective study, med...
متن کاملDosimetric Effects of Rotational Setup Error in Volumetric Modulated Arc Radiotherapy on Brain Tumor Patients
Introduction: This study examined the dosimetric effects based on the rotational setup error to correct patient setup errors occur during volumetric modulated arc radiotherapy (VMAT) for brain tumor patients. Material and Methods: This study included 1129 cases of cone beam computed tomography (CBCT) images obtained from 46 brain tumor patients, who experienced VMAT and used the 6DoF (degree o...
متن کاملDosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol
Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- SpringerPlus
دوره 5 شماره
صفحات -
تاریخ انتشار 2016