Dosimetric Comparison of Different Prescription Modes in Lung Stereotactic Body Radiation Therapy
نویسندگان
چکیده
The purpose of this study was to compare the dose-volume statistics of stereotactic body radiotherapy (SBRT) for lung cancer between planning target volume (PTV): D95 and gross tumor volume (GTV): D99 dose prescriptions using Monte Carlo (MC) calculation. Plans for 183 patients treated between October 2010 and April 2013 were generated based on four-dimensional (4D) computed tomography (CT) under free breathing. A uniform margin of 8 mm was added to the internal target volume (ITV) to generate PTV. A leaf margin of 2 mm was added to the PTV. The plans were calculated with two different dose prescription methods: 40 Gy to cover 95% of the PTV (PTV prescription) and 44 Gy to cover 99% of the GTV (GTV prescription). A 6-MV photon beam was used. A dose-volume histogram (DVH) analysis was performed for dose to the GTV using PTV and GTV dose prescriptions. For each treatment plan, we evaluated the minimum dose to 99% of the GTV (D99). The D99 of GTV was 44.5 ± 1.9 Gy and 44.0 ± 0.0 Gy for PTV and GTV prescriptions, respectively. The dose to the GTV had wide variations with PTV prescription. We recommend that GTV based dose prescription should be used to standardize dose to the tumor and to achieve highly conformal dose distributions in SBRT for lung cancer.
منابع مشابه
Dosimetric comparison of CT-guided iodine-125 seed stereotactic brachytherapy and stereotactic body radiation therapy in the treatment of NSCLC
This study aimed to assess the dosimetric differences between iodine-125 seed stereotactic brachytherapy (SBT) and stereotactic body radiation therapy (SBRT) in the treatment of non-small cell lung cancer (NSCLC). An SBT plan and an SBRT plan were generated for eleven patients with T1-2 NSCLC. Prescription of the dose and fractionation (fr) for SBRT was 48Gy/4fr. The planning aim for SBT was D9...
متن کاملDosimetric effects of rotational offsets in stereotactic body radiation therapy (SBRT) for lung cancer.
To quantitatively evaluate dosimetric effects of rotational offsets in stereotactic body radiation therapy (SBRT) for lung cancer. Overall, 11 lung SBRT patients (8 female and 3 male; mean age: 75.0 years) with medially located tumors were included. Treatment plans with simulated rotational offsets of 1°, 3°, and 5° in roll, yaw, and pitch were generated and compared with the original plans. Bo...
متن کاملDosimetric evaluation of the impacts of different heterogeneity correction algorithms on target doses in stereotactic body radiation therapy for lung tumors
Heterogeneity correction algorithms can have a large impact on the dose distributions of stereotactic body radiation therapy (SBRT) for lung tumors. Treatment plans of 20 patients who underwent SBRT for lung tumors with the prescribed dose of 48 Gy in four fractions at the isocenter were reviewed retrospectively and recalculated with different heterogeneity correction algorithms: the pencil bea...
متن کاملThe evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy
Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...
متن کاملAn Integrated Simulation System Based on Digital Human Phantom for 4D Radiation Therapy of Lung Cancer
Purpose: To develop and test an integrated simulation system based on the digital Extended Cardio Torso (XCAT) phantom for 4-dimensional (4D) radiation therapy of lung cancer. Methods: A computer program was developed to facilitate the characterization and implementation of the XCAT phantom for 4D radiation therapy applications. To verify that patient-specific motion trajectories are reproducib...
متن کامل