A 31P nuclear magnetic resonance in vivo study of cerebral ischaemia in the gerbil.

نویسندگان

  • K R Thulborn
  • G H du Boulay
  • L W Duchen
  • G Radda
چکیده

We have used the noninvasive method of 31phosphorus nuclear magnetic resonance (31P NMR) in vivo to follow changes in phosphorous metabolite concentrations and the intracellular pH in the right and left hemispheres and in the cerebellum of gerbil brains after the occlusion of the right carotid artery. Spatial resolution over the brain was possible using surface coils. Ligation, which is know to cause ischaemia in this species in the ipsilateral hemisphere, resulted in the diminution of phosphocreatine and adenine nucleotides and a decrease in tissue pH. Less acidification occurred in the contralateral hemisphere and in the cerebellum. The high-energy metabolite concentrations, phosphocreatine and adenosine triphosphate (ATP), declined in unison in the ischaemic region, in marked contrast to the sequence of events in skeletal muscle, in which phosphocreatine buffers against an immediate fall in ATP concentration. In a separate series of gerbils, 31P NMR spectra were followed for exactly 1 h after carotid ligation. The animals were then sacrificed and brain grey matter specific gravity was rapidly measured to assess the development of oedema. There was a clear correlation between abnormality of spectra and the presence of oedema. It cannot, however, be confidently asserted that a normal spectrum is never seen in oedematous gerbil brains. 31P NMR spectra specific gravity and histological changes shown by light microscopy have been correlated and show that useful signals are received from a depth of at least 4 mm or more from the 10-mm diameter coil.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of unidirectional Pi to ATP flux in human visual cortex at 7 T by using in vivo 31P magnetic resonance spectroscopy.

Taking advantage of the high NMR detection sensitivity and the large chemical shift dispersion offered by ultra-high field strength of 7 T, the effect of magnetization transfer on inorganic phosphate (Pi) resonance during saturation of gamma-ATP resonance, mediated by the ATP synthesis reaction, was observed noninvasively in the human primary visual cortex by using in vivo 31P magnetic resonanc...

متن کامل

In Vivo 31P-Nuclear Magnetic Resonance Studies on Energy Metabolism of Ischemic Gerbil Brain: Comparison between Unilateral and Bilateral Common Carotid Artery Occlusion Models

The changes of cerebral energy state under bilateral and unilateral common carotid artery occlusion-reflow models in Mongolian gerbils were studied using in vivo 31 P nuclear magnetic resonance spectrometry (3IP-MRS). All ten gerbils used in the bilateral common carotid artery occlusion-reflow model showed relatively uniform ischemic patterns, i.e., depletion of phosphocreatine (PCr) and adenos...

متن کامل

NUCLEAR MAGNETIC RESONANCE STUDY OF THE STRUCTURE OF GLYOXALDIHYDRAZONE

Study of the nuclear magnetic resonance spectra of glyoxaldihydrazone in dimethylsulfoxide and deuterochlorofonn leads to the conclusion that this compound exists predominantly in non-chelate structure

متن کامل

31P-nuclear magnetic resonance spectroscopy of blood: a species comparison.

31P-nuclear magnetic resonance (NMR) spectroscopy isfrequently used as a tool in the study of organs from various animal species and humans. Because signals arising from the presence of blood are visible in in vivo 31P-NMR spectra of blood-filled organs, such as the heart, it is necessary to correct these spectra for the contribution of blood to the signal. It is unknown whether species differe...

متن کامل

Designing and Fabrication of a New Radiofrequency Planar microcoil for mini-Nuclear Magnetic Resonance

Introduction Radiofrequency planar microcoils are used to increase the resolution of magnetic resonance images of small samples. In this study, we aimed to design and fabricate a spiral planar microcoil constructed on a double-sided printed circuit board (PCB). It has four rings with an internal diameter of 241 microns tuned and matched at 63.8 MHz. Materials and Methods To achieve the maximum ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism

دوره 2 3  شماره 

صفحات  -

تاریخ انتشار 1982