15: RRTMGP: A High-Performance Broadband Radiation Code for the Next Decade
نویسندگان
چکیده
We are developing a high-performance broadband radiation code for the current generation of computational architectures. This code, called RRTMGP, will be a completely restructured and modern version of the accurate RRTMG radiation code (Mlawer et al., 1997; Iacono et al., 2008) that has been implemented in many General Circulation Models (GCMs) including the Navy Global Environmental Model (NAVGEM), the NCAR Community Earth System Model (CESM), and NOAA’s Global Forecast System (GFS). Our proposed development will significantly lessen a key bottleneck in these highly complex and coupled models, namely the large fraction of computational time currently required for the calculation of radiative fluxes and heating rates.
منابع مشابه
A Suitable Coding Scheme for Broadband Power-line Communication
This paper introduces three coding strategies for using the Luby Transform (LT) code in a relay aided power-line communication scheme. In the first method, the relay decodes the received packets and re-encodes them for transmission towards the destination. In the second method, the relay only forwardes a random linear combination of its received packets towards the destination, while in the thi...
متن کاملDesigned free-lead composite shields for diagnostic medicine radiation fields by using MCNPX code
Introduction: Nowadays, applications of free-lead radiation shields are increased specially for weighting factor and toxicity of lead elements. Although touching the lead may be results in the nervousand blood system of body, it is not exactly proven yet. Protective measures are the fundamental parts of radiation protection. On the other hand, high weighting factor of lead sh...
متن کاملRadiation Shielding Features of Ordinary and High-Density Concretes Loaded With PbO Micro and Nanoparticles against High-Energy Photons
Introduction: The present study aimed to evaluate the impact of PbO nano and micro-sized fillers on ordinary and heavy concretes for different photon energies. Material and Methods: The MCNPX Monte Carlo code (version 2.6.0) was used for all simulations in the present study. A model of narrow-beam geometry was validated and utilized to calcul...
متن کاملThe dosimetry assessment of Varian Linear Accelerators of 6, 15 and 20 MV by Monte Carlo Method
Introduction: Monte Carlo method is often applied in radiation therapy as utilized in all the branches of science. An important requirement for successful radiotherapy is carefully examine the dose distribution specifications and decrease the difference between these features with experience to an acceptable level. In this study, the characteristics of 6, 15 and 20 MeV incident x-rays are prov...
متن کاملThe promise of downlink MU-MIMO for high-capacity next generation mobile broadband networks based on IEEE 802.16 m
The dramatic increase of the demand for mobile broadband services poses stringent requirements on the performance evolution of currently deployed mobile broadband networks, such as Mobile WiMAX Release 1 and 3GPP LTE Release 8. Although the combination of single-user multiple-input multiple-output (SU-MIMO) and orthogonal frequency division multiple access (OFDMA) provide the appropriate techno...
متن کامل