Bayesian meta-analysis of the accuracy of a test for tuberculous pleuritis in the absence of a gold standard reference.
نویسندگان
چکیده
Absence of a perfect reference test is an acknowledged source of bias in diagnostic studies. In the case of tuberculous pleuritis, standard reference tests such as smear microscopy, culture and biopsy have poor sensitivity. Yet meta-analyses of new tests for this disease have always assumed the reference standard is perfect, leading to biased estimates of the new test's accuracy. We describe a method for joint meta-analysis of sensitivity and specificity of the diagnostic test under evaluation, while considering the imperfect nature of the reference standard. We use a Bayesian hierarchical model that takes into account within- and between-study variability. We show how to obtain pooled estimates of sensitivity and specificity, and how to plot a hierarchical summary receiver operating characteristic curve. We describe extensions of the model to situations where multiple reference tests are used, and where index and reference tests are conditionally dependent. The performance of the model is evaluated using simulations and illustrated using data from a meta-analysis of nucleic acid amplification tests (NAATs) for tuberculous pleuritis. The estimate of NAAT specificity was higher and the sensitivity lower compared to a model that assumed that the reference test was perfect.
منابع مشابه
Contrastive analysis of diagnostic tests evaluation without gold stand-ard: review article
Considering the advancement of medical sciences, diagnostic tests have been developed to distinguish patients from healthy population. Therefore, Determining and evaluation of the diagnostic accuracy tests is of great importance. The accuracy of a test under evaluation is determined through the amount of agreement between its results with the results of the gold standard, and this test accuracy...
متن کاملApplication of Bayesian Latent Variable Model for Early Detection of Gestational Diabetes Mellitus Without A Perfect Reference Standard Test by β‐human Chorionic Gonadotropin
Background and Objectives: Gestational diabetes mellitus (GDM) is a medical problem in pregnancy, and its late diagnosis can cause adverse effects in the mother and fetus. The purpose of this research was to estimate the accuracy parameters of a biomarker for early prediction of gestational diabetes in the absence of a perfect reference standard test. Methods: This study was conducted in 52...
متن کاملTh1/Th2 Imbalance and Elevated PD-L1 in Pleural Effusion Predict the Risk of Multi-Drug Resistant Tuberculous Pleuritis
Background: Patient immune status might be indicative of the variance in bacterial genetics in drug-resistant tuberculous pleuritis and could be used for predicting the risk of multi-drug resistant tuberculous pleuritis (MDR-TB). Objective: To determine the significance of Th2/Th1 ratio and concentration of PD-L1 in the pleural effusions for prediction of MDR-T...
متن کاملBayesian meta-analysis of diagnostic tests allowing for imperfect reference standards.
There is an increasing interest in meta-analyses of rapid diagnostic tests (RDTs) for infectious diseases. To avoid spectrum bias, these meta-analyses should focus on phase IV studies performed in the target population. For many infectious diseases, these target populations attend primary health care centers in resource-constrained settings where it is difficult to perform gold standard diagnos...
متن کاملمقایسه روش های مختلف آماری در انتخاب ژنومی گاوهای هلشتاین
Genomic selection combines statistical methods with genomic data to predict genetic values for complex traits. The accuracy of prediction of genetic values in selected population has a great effect on the success of this selection method. Accuracy of genomic prediction is highly dependent on the statistical model used to estimate marker effects in reference population. Various factors such a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biometrics
دوره 68 4 شماره
صفحات -
تاریخ انتشار 2012