Validity of synthetic bone as a substitute for osteoporotic cadaveric femoral heads in mechanical testing
نویسندگان
چکیده
INTRODUCTION The objective of this study was to determine if a synthetic bone substitute would provide results similar to bone from osteoporotic femoral heads during in vitro testing with orthopaedic implants. If the synthetic material could produce results similar to those of the osteoporotic bone, it could reduce or eliminate the need for testing of implants on bone. METHODS Pushout studies were performed with the dynamic hip screw (DHS) and the DHS Blade in both cadaveric femoral heads and artificial bone substitutes in the form of polyurethane foam blocks of different density. The pushout studies were performed as a means of comparing the force displacement curves produced by each implant within each material. RESULTS The results demonstrated that test material with a density of 0.16 g/cm(3) (block A) produced qualitatively similar force displacement curves for the DHS and qualitatively and quantitatively similar force displacement curves for the DHS Blade, whereas the test material with a density of 0.08 g/cm(3) (block B) did not produce results that were predictive of those recorded within the osteoporotic cadaveric femoral heads. CONCLUSION This study demonstrates that synthetic material with a density of 0.16 g/cm(3) can provide a good substitute for cadaveric osteoporotic femoral heads in the testing of implants. However we do recognise that no synthetic material can be considered as a definitive substitute for bone, therefore studies performed with artificial bone substrates may need to be validated by further testing with a small bone sample in order to produce conclusive results.
منابع مشابه
A polycaprolactone bio-nanocomposite bone substitute fabricated for femoral fracture approaches: Molecular dynamic and micromechanical Investigation
The application of porous bio-nanocomposites polymer has greatly increased in the treatment of boneabnormalities and bone fracture. Therefore, predicting the mechanical properties of these bio-nanocompositesare very important prior to their fabrication. Investigation of mechanical properties like (elasticmodulus and hardness) is very costly and time-consuming in experimental t...
متن کاملA surrogate long-bone model with osteoporotic material properties for biomechanical testing of fracture implants.
In vitro comparative testing of fracture fixation implants is limited by the highly variable material properties of cadaveric bone. Bone surrogate specimens are often employed to avoid this confounding variable. Although validated surrogate models of normal bone (NB) exist, no validated bone model simulating weak, osteoporotic bone (OPB) is available. This study presents an osteoporotic long-bo...
متن کاملA micro-architectural evaluation of osteoporotic human femoral heads to guide implant placement in proximal femoral fractures
BACKGROUND AND PURPOSE The micro-architecture of bone has been increasingly recognized as an important determinant of bone strength. Successful operative stabilization of fractures depends on bone strength. We evaluated the osseous micro-architecture and strength of the osteoporotic human femoral head. MATERIAL AND METHODS 6 femoral heads, obtained during arthroplasty surgery for femoral neck...
متن کاملMechanical considerations in impaction bone grafting.
In impaction grafting of contained bone defects after revision joint arthroplasty the graft behaves as a friable aggregate and its resistance to complex forces depends on grading, normal load and compaction. Bone mills in current use produce a distribution of particle sizes more uniform than is desirable for maximising resistance to shear stresses. We have performed experiments in vitro using m...
متن کاملValidity of Panoramic Indices to Evaluate the Association of Bone Mineral Density with Morphology of the Mandible in Osteoporotic Patients
Objective: Osteoporosis is the most common metabolic disease of the bone decreasing bone mineral density (BMD) particularly in postmenopausal women. On the other hand, panoramic radiography has several applications in dentistry. It appears that by calculating some indices on panoramic radiographs, we may be able to predict the risk of osteoporosis in high-risk individuals. The present study w...