Flexible graphite modified by carbon black paste for use as a thermal interface material

نویسنده

  • Kesong Hu
چکیده

Polyol-ester-based carbon black pastes are used to either coat or penetrate flexible graphite, thereby increasing the thermal contact conductance of flexible graphite between copper surfaces. Paste penetration by up to an effective paste thickness (the volume of the penetrated paste divided by the geometric area of the flexible graphite) of 5 lm increases the conductance by up to 350%, 98% and 36% for thicknesses of 50, 130 and 300 lm, respectively. Paste coating up to 10 lm increases the conductance by up to 200%, 120% and 65% for thicknesses of 50, 130 and 300 lm, respectively. The paste penetration is more effective than the paste coating in enhancing the conductance, when the thickness is below 130 lm. At thickness P130 lm, paste penetration and paste coating are similarly effective. These results stem from the relatively low interfacial thermal resistivity provided by paste penetration and the relatively high through-thickness thermal conductivity provided by paste coating. Paste penetration decreases the thermal conductivity of flexible graphite, but paste coating does not affect the conductivity. Both penetration and coating decrease the interfacial resistivity. The highest thermal contact conductance is 1.4 · 10 W/m K, as provided by paste-penetrated flexible graphite of thickness 26 lm. 2010 Elsevier Ltd. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dielectric and electrical conduction behavior of carbon paste electrochemical electrodes, with decoupling of carbon, electrolyte and interface contributions

Article history: Received 7 December 2013 Accepted 29 January 2014 Available online 6 February 2014 The electrical conduction and dielectric (capacitive) properties of electrolyte-filled carbon paste electrochemical electrodes are reported, with the carbon, electrolyte (15% H2SO4), carbon–electrolyte interface and carbon–contact(metal) interface contributions fully decoupled for the first time....

متن کامل

Multiwall Carbon Nanotubes Modified Carbon Paste Electrode for Determination of Copper(II) by Potentiometric and Impedimetric Methods

A chemically modified carbon paste electrode with multiwall carbon nanotube (MWCNT) was prepared and used as a sensor for Cu2+  ion. The unique chemical and physical properties of CNT have paved the way  to  new  and  improved  sensing  devices.  A  central  composite chemometrics  design  was  applied  for  multivariate  optimization  of the  effects  of  three  significant  parameters  (...

متن کامل

A Simple and an Effective Catalyst for Determination of Cefixime in Real Samples Using of Modified Carbon Paste Electrode with Cobalt Impregnated Zeolite

Carbon paste electrode modified with cobalt impregnated zeolite was prepared by mixing of cobalt_zeolite (Co_Z) and graphite powder with different percent. The electrochemical oxidation of cefixime at such electrodes was investigated using the cyclic voltammetric and amperometric techniques. It is not electrochemically active towards cefixime oxidation in 0.1 M phosphate buffer solution (pH=7) ...

متن کامل

Determination of ascorbic acid by a modified multiwall carbon nanotube paste electrode using cetrimonium iodide/iodine

A new modified graphite-multiwall carbon nanotube paste electrode for the determination of ascorbic acid (AA) based on cetrimonium iodide-iodine is described. The electrochemical response characteristics of the modified electrode toward AA were investigated by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) in phosphate buffer solution (pH 2.0). When compared to activated carbo...

متن کامل

Silica Nanoparticles Modified Carbon Paste Electrode as a Voltammetric Sensor for Determination of Diclofenac

The present study describes the use of a new carbon paste electrode modified by means of Silica nanoparticles prepared by a simple and rapid procedure for the determination of sodium diclofenac (DCF). Moreover, the present study focuses on the characterization of electrochemical impedance spectroscopy (EIS) and scanning electron microscopy (SEM) of the prepared Silica NPs-CPE. In this work, The...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011