Biophysical Assessment and Predicted Thermophysiologic Effects of Body Armor

نویسندگان

  • Adam W. Potter
  • Julio A. Gonzalez
  • Anthony J. Karis
  • Xiaojiang Xu
  • Neil T Wright
چکیده

INTRODUCTION Military personnel are often required to wear ballistic protection in order to defend against enemies. However, this added protection increases mass carried and imposes additional thermal burden on the individual. Body armor (BA) is known to reduce combat casualties, but the effects of BA mass and insulation on the physical performance of soldiers are less well documented. Until recently, the emphasis has been increasing personal protection, with little consideration of the adverse impacts on human performance. OBJECTIVE The purpose of this work was to use sweating thermal manikin and mathematical modeling techniques to quantify the tradeoff between increased BA protection, the accompanying mass, and thermal effects on human performance. METHODS Using a sweating thermal manikin, total insulation (IT, clo) and vapor permeability indexes (im) were measured for a baseline clothing ensemble with and without one of seven increasingly protective U.S. Army BA configurations. Using mathematical modeling, predictions were made of thermal impact on humans wearing each configuration while working in hot/dry (desert), hot/humid (jungle), and temperate environmental conditions. RESULTS In nearly still air (0.4 m/s), IT ranged from 1.57 to 1.63 clo and im from 0.35 to 0.42 for the seven BA conditions, compared to IT and im values of 1.37 clo and 0.45 respectively, for the baseline condition (no BA). CONCLUSION Biophysical assessments and predictive modeling show a quantifiable relationship exists among increased protection and increased thermal burden and decreased work capacity. This approach enables quantitative analysis of the tradeoffs between ballistic protection, thermal-work strain, and physical work performance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Case study: a novel biomechanical approach for evaluating extended body armor systems.

To combat the devastating effects of improvised explosive devices (IEDs), body armor that provides extended coverage has been developed. However, this extended coverage increases the armor's weight and may restrict movement. Throughout this case study, a novel technique to assess several armor systems was investigated. Four soldiers performed shoulder and trunk movements while wearing each of t...

متن کامل

ارزیابی بی‌خطری کرم‌های ضددرماتیت ازطریق اندازه‌گیری شاخص‌های بیوفیزیکی پوست: کارآزمایی بالینی دارای گروه شاهد فاز I

Background and Aim: Dermatitis or eczema is an itchy skin disorder which is usually caused by the skin inflammatory reaction in response to combination of genetic and environmental factors. This study was aimed to assess the safety of anti-dermatitis creams and possible side effects on human volunteers through measuring the skin biophysical parameters with non-invasive methods. Methods: Two ...

متن کامل

The relationship between the full biophysical profile and rapid biophysical profile in antepartum fetal surveillance

Objective: one of the best tests for the assessment of a fetus is the biophysical profile test which has a significant effect on fetus health and the outcome of pregnancy. The present study was designed to determine the relationship between the full biophysical profile and the rapid biophysical profile tests in antepartum fetal surveillance. Patients and Methods: In this prospective study, Sin...

متن کامل

Task-specific effects of modular body armor.

Eleven recreationally active males performed 11 circuits of military work, wearing torso armor on one occasion, and full armor on another. Performance was measured by the time taken to complete individual tasks, and the overall time to completion (TTC) for each circuit. Heart rate, intestinal temperature, ratings of perceived exertion (RPE), and thermal sensation were recorded after each circui...

متن کامل

The addition of body armor diminishes dynamic postural stability in military soldiers.

Poor postural stability has been identified as a risk factor for lower extremity musculoskeletal injury. The additional weight of body armor carried by Soldiers alters static postural stability and may predispose Soldiers to lower extremity musculoskeletal injuries. However, static postural stability tasks poorly replicate the dynamic military environment, which places considerable stress on th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015