Operational Problems in Pumping Non-settling Slurries Resolved Using an Improved Laminar Flow Pipe Fitting Loss Model
نویسندگان
چکیده
A case history is presented pertaining to five pumping systems that operated satisfactorily until a new production requirement was imposed on the pumping systems. A new slurry product initially developed at lab scale was introduced into the production plant for an initial trial run. Problems began to surface immediately on three out of five batch process pumping systems when the slurry could not be pumped through the plant at contract rate. Additionally, significant "heels" (unwanted fluid levels) were left in some of the suction vessels that were unable to be pumped out, resulting in considerable yield losses. This manufacturing problem had not been anticipated by the team, and without quick resolution, a loss of customer confidence and a significant delay in the new product would have resulted. Investigation and analysis of the system revealed two major problem areas in pumping non-settling slurries in laminar regimes: • Initial prediction of head losses through suction piping fittings was flawed using traditional hydraulic loss methods. The original calculations for NPSHA values for the pumps predicted adequate NPSH margin. The fluid was non-Newtonian and was operating in the laminar regime. Upon further investigation, a weakness was revealed in predictions of fitting losses for laminar flow through the pipe fittings. An improved model for predicting losses through pipe fittings was identified and implemented. The improved model matched operational data much better and provided the critical insight needed to resolve the operational problems and get the facility operating. • Piping arrangements that allow for features such as clean-out ports (e.g., branch flow tees) can be counterproductive to unrestricted flow of the process liquid in systems with non-settling slurries operating in laminar regimes. Tees, elbows, diameter changes, and other fittings can introduce significant head losses in the pumping system. The authors present an improved method for analyzing fitting losses in pumping systems when dealing with nonsettling slurries operating in the laminar regime. In addition, design considerations are presented to minimize the impact that piping has on the pumping system when handling non-settling slurries operating in the laminar regime.
منابع مشابه
Development length of laminar magnetohydrodynamics pipe flows
In this article, a laminar magnetohydrodynamics (MHD) developing flow of an incompressible electrically conducting fluid subjected to an external magnetic field is considered. The aim of the study is to propose a correlation for computing the development length of the laminar MHD developing flow in a pipe. A numerical approach is considered to solve the problem. In the first step, the numerical...
متن کاملA Numerical Study of the Effect of Aspect Ratio on Heat Transfer in an Annular Flow Through a 270-Degree Curved Pipe.
In the present paper, a three dimensional annular developing incompressible laminar flow through 270- degree curved pipe is numerically simulated. The dimensionless governing equations of continuity, momentums and energy are driven in toroidal coordinates. The governing equations are discretized by projection algorithm using forward difference in time and central difference in space. A three-di...
متن کاملAn Experimental Investigation and Prediction of Asphaltene Deposition during Laminar Flow in the Pipes Using a Heat Transfer Approach
In this study, asphaltene deposition from crude oil has experimentally and theoretically been studied using a test loop and an accurate temperature monitoring during a laminar flow. The effects of oil velocity and surface temperature on the thickness of asphaltene deposition were investigated. The results show that asphaltene deposition thickness increases by increasing surface temperature. As ...
متن کاملFluid flow and heat transfer characteristics in a curved rectangular duct using Al2O3-water nanofluid
In the present research, the laminar forced convective heat transfer and fluid flow characteristics for Al2O3-water nanofluid flowing in different bend (i.e., 180o and 90o) pipes have been investigated numerically in a three-dimensional computational domain using the finite volume technique. The effects of different pertinent parameters, such as the Reynolds number of the duct, volume fraction ...
متن کاملNumerical Simulation in Steady flow of Non-Newtonian Fluids in Pipes with Circular Cross-Section
In the chemical and process industries, it is often required to pump fluids over long distances from storage to various processing units and/or from one plant site to another. There may be a substantial frictional pressure loss in both the pipe line and in the individual units themselves. It is thus often necessary to consider the problems of calculating the power requirements for pumping throu...
متن کامل