BACKGROUND Observational studies of new coronary stents are necessary to assess performance in a variety of complex patient and lesion types. Furthermore, the optimal dose and duration of thienopyridine treatment is unclear, particularly in patients with complex clinical conditions. The TAXUS Libertē Post-Approval Study is designed to provide 5-year data on the TAXUS Liberté paclitaxel-eluting stent with concomitant prasugrel therapy in routine clinical practice and to contribute data to the DAPT study. STUDY DESIGN The TAXUS Libertē Post-Approval Study is a prospective, multicenter, observational study. Enrollment of approximately 4,200 patients receiving ≥1 TAXUS Liberté stents is planned. All patients without a contraindication will be prescribed prasugrel plus aspirin for 1 year. The 12-month primary end point of cardiac death or myocardial infarction in on-label stent patients will be compared with historical TAXUS Express stent data from the TAXUS ATLAS and TAXUS ARRIVE studies. Secondary clinical end points include stent thrombosis, all-cause death, stroke, revascularization, and bleeding in all patients. In addition, this study will be the first to evaluate prasugrel use in a routine practice setting (including 5 and 10 mg daily doses) and will contribute data to the DAPT Study, comparing 12 versus 30 months of dual antiplatelet therapy after drug-eluting stent placement. SUMMARY The TAXUS Libertē Post-Approval Study will be the first to provide long-term real-world data on use of the TAXUS Liberté Stent with prasugrel treatment. The study is currently enrolling, and primary end point data are expected in mid 2013.
منابع مشابه
Prasugrel plus aspirin beyond 12 months is associated with improved outcomes after TAXUS Liberté paclitaxel-eluting coronary stent placement.
BACKGROUND The TAXUS Liberté Post Approval Study (TL-PAS) contributed patients treated with TAXUS Liberté paclitaxel-eluting stent and prasugrel to the Dual Antiplatelet Therapy Study (DAPT) that compared 12 and 30 months thienopyridine plus aspirin therapy after drug-eluting stents. METHODS AND RESULTS Outcomes for 2191 TL-PAS patients enrolled into DAPT were assessed. The DAPT coprimary com...
متن کاملReduced risk of restenosis in small vessels and reduced risk of myocardial infarction in long lesions with the new thin-strut TAXUS Liberté stent: 1-year results from the TAXUS ATLAS program.
OBJECTIVES The TAXUS ATLAS Small Vessel (SV) and Long Lesion (LL) multicenter studies compared the performance of the thin-strut (0.0038 inch) TAXUS Liberté 2.25-mm stent (Boston Scientific; Natick, Massachusetts) and the TAXUS Liberté 38-mm long stent (Boston Scientific; Natick, Massachusetts) with the earlier paclitaxel-eluting TAXUS Express (Boston Scientific) stent that has identical polyme...
متن کاملNew stent design for use in small coronary arteries during percutaneous coronary intervention
Patients with diabetes mellitus, of female gender, increased age, and/or with peripheral vascular disease often develop coronary stenoses in small caliber vessels. This review describes treatment of these lesions with the paclitaxel-eluting 2.25 mm TAXUS(®) Liberté(®) Atom™ stent. Given the same stent composition, polymer, antirestenotic drug (paclitaxel), and release kinetics as the first-gene...
متن کاملSix-month results of the NEVO Res-Elution I (NEVO RES-I) trial: a randomized, multicenter comparison of the NEVO sirolimus-eluting coronary stent with the TAXUS Liberté paclitaxel-eluting stent in de novo native coronary artery lesions.
BACKGROUND Drug-eluting stents reduce restenosis and reintervention rates but are complicated by stent thrombosis, which may be related to polymer coating. The NEVO sirolimus-eluting coronary stent (NEVO SES) is designed to improve long-term percutaneous coronary intervention safety by combining sirolimus release from reservoirs with bioabsorbable polymer to reduce spatial and temporal polymer ...
متن کاملRandomized comparison of a polymer-free sirolimus-eluting stent versus a polymer-based paclitaxel-eluting stent in patients with diabetes mellitus: the LIPSIA Yukon trial.
OBJECTIVES The objective of the study was to assess noninferiority of the polymer-free sirolimus-eluting Yukon Choice stent (Translumina GmbH, Hechingen, Germany) compared with the polymer-based Taxus Liberté stent (Boston Scientific, Natick, Massachusetts) with regard to the primary endpoint, in-stent late lumen loss, at 9 months in patients with diabetes mellitus. BACKGROUND The Yukon Choic...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American heart journal
دوره 163 2 شماره
صفحات -
تاریخ انتشار 2012