Detection and localization of prolonged epicardial electrograms with 64-lead body surface signal-averaged electrocardiography.
نویسندگان
چکیده
BACKGROUND Prolonged, fractionated ventricular electrograms often are detectable after myocardial infarction and are a marker for an arrhythmia-prone state. QRS late potentials detected on the body surface with signal-averaged electrocardiography (SAECG) are thought to arise from the diseased tissue that generates prolonged ventricular electrograms and as such are also a marker for arrhythmias. A limitation of the current SAECG technique is that recordings are obtained from only three bipolar lead pairs. Because late potentials probably arise from multiple small sources in the heart, more extensive sampling of the body surface may contribute additional information to the SAECG: The present study investigates the additional sensitivity of SAECG using 64 body surface leads in detecting prolonged epicardial electrograms and examines its use in determining the epicardial location of prolonged electrograms. METHODS AND RESULTS Dogs were studied before and 5-10 days after either lateral left ventricular (n = 13) or right ventricular (n = 8) myocardial infarction. Greater prolongation of signal-averaged QRS duration was detected with 64-lead SAECG (postinfarction QRS duration, 100.3 +/- 16.3 msec) than with three-lead SAECG (postinfarction QRS duration, 89.4 +/- 10.1, p = 0.0005). Nineteen of the 21 dogs (90%) had prolonged epicardial electrograms detected over the infarct. The correlation between epicardial electrogram duration and signal-averaged QRS duration calculated from individual leads was much better for 64-lead SAECG (r = 0.88, p less than 0.0001) than for three-lead SAECG (r = 0.53, p = 0.01), and the difference was most marked in cases with longer electrogram durations (more than 100 msec). Local late potential maxima on the thorax after lateral left ventricular infarction were located to the left and inferior compared with those after right ventricular infarction (p = 0.006). CONCLUSIONS SAECG with more extensive recording from the body surface using 64 leads detects greater QRS prolongation than three-lead SAECG, and the longer QRS durations detected correspond to the duration of prolonged epicardial electrograms. Body surface location of late potentials corresponds to the epicardial location of the prolonged electrograms. This application of body surface mapping techniques to SAECG may permit more sensitive detection of arrhythmia-prone states and may aid in identifying arrhythmia sources.
منابع مشابه
Estimates of repolarization dispersion from electrocardiographic measurements.
BACKGROUND Repolarization dispersion (Rd) is frequently mentioned as a predictor of cardiac abnormalities. We present a new measure of Rd based on the root-mean-square (RMS) curve of an ECG lead set and compare its performance with that of the commonly used QT dispersion (QTd) measure with the use of recovery times measured from directly recorded canine electrograms. METHODS AND RESULTS Using...
متن کاملEpicardial electrogram of the right ventricular outflow tract in patients with the Brugada syndrome: using the epicardial lead.
OBJECTIVES We tried to record an epicardial electrogram directly, and we examined local electrograms before and after administration of a class IC anti-arrhythmic drug in patients with the Brugada syndrome. BACKGROUND Electrical heterogeneity of the epicardium in the right ventricular outflow tract (RVOT) has been thought to be related to the Brugada syndrome. However, an epicardial abnormali...
متن کاملComparison of Body-Surface and Epicardial Measures
Background—Body-surface ECG measures (QT dispersion [QTd], QRST integrals) have been used as indices of myocardial repolarization abnormalities with the goal of identifying patients at risk of fatal arrhythmias. The clinical utility of these measures has been questioned. We investigate the complex relationship between epicardial and body-surface potentials in the context of regionally abnormal ...
متن کاملImaging dispersion of myocardial repolarization, I: comparison of body-surface and epicardial measures.
BACKGROUND Body-surface ECG measures (QT dispersion [QTd], QRST integrals) have been used as indices of myocardial repolarization abnormalities with the goal of identifying patients at risk of fatal arrhythmias. The clinical utility of these measures has been questioned. We investigate the complex relationship between epicardial and body-surface potentials in the context of regionally abnormal ...
متن کاملClinical Implementation of Electrocardiographic Imaging (ecgi): Design, Development, and Verification of a Person-specific Electrocardiographic Imaging System
by DAVID CHARLES KAELBER The inverse problem in electrocardiography is the noninvasive reconstruction of epicardial potentials, electrograms, and activation isochrones from measured body surface potentials. The goal of clinical inverse solutions is to image the electrical activity on the epicardial surface of the in vivo heart, noninvasively. Despite advances in the theory and techniques of inv...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 84 2 شماره
صفحات -
تاریخ انتشار 1991