Two Cases of Suprachoroidal Hemorrhage after Implantation of an Ex-Press Miniature Glaucoma Device and an Intraocular Lens
نویسندگان
چکیده
Suprachoroidal hemorrhage is a rare complication of ophthalmic surgery in general and of glaucoma filtration procedures in particular. We present herein two cases of suprachoroidal hemorrhage in aphakic patients after simultaneous implantation of an Ex-Press miniature glaucoma device and an intraocular lens. Although a rare complication, we have now seen two cases develop in previously aphakic patients when we have attempted to place an Ex-Press miniature glaucoma device in conjunction with placement of a secondary intraocular lens. These two cases suggest that greater caution is warranted when attempting to surgically implant an express mini shut in the aphakic patient.
منابع مشابه
Ex-PRESS miniature glaucoma shunt in treatment of refractory glaucoma.
Refractory glaucoma in a complicated type of glaucoma of different ethyologies with one same characteristic--intraocular pressure of great resistance to therapy. There are different methods of treatment in such glaucomas, primary surgical options. Ex-PRESS miniature glaucoma shunt implantation was our treatment of choice. In our group of patients we achieved stabile intraocular pressure values ...
متن کاملDelayed suprachoroidal hemorrhage after glaucoma filtration procedures.
OBJECTIVES To determine the incidence of, risk factors for, and outcomes of delayed suprachoroidal hemorrhage (DSCH) after glaucoma filtration surgery. DESIGN Retrospective case-control study. PARTICIPANTS All patients undergoing glaucoma filtration procedures between 1986 and 2000 at Indiana University who were diagnosed postoperatively with suprachoroidal hemorrhage. A total of 66 patient...
متن کاملThe best of the best: a review of select glaucoma case reports published in 2014.
This review article summarizes four key case reports published in the field of glaucoma in the year 2014. The first article describes successful early drainage of delayed suprachoroidal hemorrhage in 7 patients who underwent glaucoma surgery. The second describes the use of a corneal patch graft to repair leaking or hypotonous blebs in patients who underwent glaucoma filtration surgery. The thi...
متن کاملEvaluation of Ex-PRESS mini glaucoma shunt implantation in refractory postpenetrating keratoplasty glaucoma.
PURPOSE To evaluate the intraocular pressure (IOP) control and graft survival after Ex-PRESS mini glaucoma shunt implantation in refractory postpenetrating keratoplasty glaucoma. METHODS The study included postpenetrating keratoplasty glaucoma cases unresponsive to medical antiglaucomatous therapy in whom 15 Ex-PRESS mini glaucoma shunt implantation was carried out. All glaucoma shunt implant...
متن کاملFive-year extension of a clinical trial comparing the EX-PRESS glaucoma filtration device and trabeculectomy in primary open-angle glaucoma
BACKGROUND This study compared the efficacy of the EX-PRESS(®) glaucoma filtration device and trabeculectomy in primary open-angle glaucoma up to five years after surgery. METHODS Patients from a previously reported randomized, open-label, parallel-arm clinical trial in which 78 patients received either the EX-PRESS glaucoma filtration device or underwent a trabeculectomy were followed for up...