The Fish Hook Technique of extracting broken intramedullary nails.
نویسندگان
چکیده
Removal of hardware in orthopaedic surgery is usually encountered in revision fracture surgery for non union, mal union, infection and peri-implant failure. If the hardware has broken this can make revision surgery even more demanding. Numerous techniques have been described to facilitate implant removal. A broken femoral nail is not an uncommon presentation of a delayed union or a non union. We describe a simple and innovative technique to remove the distal portion of broken intramedullary nails without causing any further trauma. This technique can be extended to include most hollow intramedullary nails.
منابع مشابه
Removal of a Broken Cannulated Intramedullary Nail: Review of the Literature and a Case Report of a New Technique
Nonunion of long bones fixed with nails may result in implant failure. Removal of a broken intramedullary nail may be a real challenge. Many methods have been described to allow for removal of the broken piece of the nail. In this paper, we are reviewing the different techniques to extract a broken nail, classifying them into different subsets, and describing a new technique that we used to rem...
متن کاملAnterograde Removal of Broken Femoral Nails without Opening the Nonunion Site: A New Technique
OBJECTIVE We describe a new technique for removing the distal fragments of broken intramedullary femoral nails without disturbing the nonunion site. METHODS This technique involves the application of an AO distractor prior to the removal of the nail fragments, with subsequent removal of the proximal nail fragment in an anterograde fashion and removal of the distal fragment through a medial pa...
متن کاملTreatment of Pediatric Open Femoral Fractures with External Fixator Versus Flexible Intramedullary Nails
Background: In children, inappropriate treatment of open femoral fractures may induce several complications. A few studies have compared the external fixator with flexible intramedullary nails in high-grade open femoral fractures of children. The present study aims at comparing results of these two treatment methods in open femoral fractures. Methods: In this descriptive analytical study, 27 ...
متن کاملA novel way to remove a broken intramedullary nail
BACKGROUND Removal of broken intramedullary nails can prove challenging and several techniques have been suggested to achieve retrieval.1 The increasing use of retrograde nails for calcaneotalotibial arthrodesis has a particular problem: the cannulation is often too narrow to allow passage of hooks or other commonly used extraction devices.2 We propose a method using equipment that is readily a...
متن کاملA simple method for removal of the distal segment of a broken femoral intramedullary nail: a case report.
ABSTRACT We report a method for removing the distal segment of a broken locked intramedullary nail secondary to nonunion of the femur following radiotherapy for fibromatosis. A Kirschner wire with one tip fashioned into a hook was used to remove the distal segment without opening with the nonunion site. Details of the procedure are described. KEY WORDS Broken intramedullary nail, removal of d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta orthopaedica Belgica
دوره 74 5 شماره
صفحات -
تاریخ انتشار 2008