The effect of polyethylene creep on tibial insert locking screw loosening and back-out in prosthetic knee joints.

نویسندگان

  • Anthony P Sanders
  • Bart Raeymaekers
چکیده

A prosthetic knee joint typically comprises a cobalt-chromium femoral component that articulates with a polyethylene tibial insert. A locking screw may be used to prevent micromotion and dislodgement of the tibial insert from the tibial tray. Screw loosening and back-out have been reported, but the mechanism that causes screw loosening is currently not well understood. In this paper, we experimentally evaluate the effect of polyethylene creep on the preload of the locking screw. We find that the preload decreases significantly as a result of polyethylene creep, which reduces the torque required to loosen the locking screw. The torque applied to the tibial insert due to internal/external rotation within the knee joint during gait could thus drive locking screw loosening and back-out. The results are very similar for different types of polyethylene.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monoblock versus modular polyethylene insert in uncemented total knee arthroplasty

Background and purpose - Backside wear of the polyethylene insert in total knee arthroplasty (TKA) can produce clinically significant levels of polyethylene debris, which can lead to loosening of the tibial component. Loosening due to polyethylene debris could theoretically be reduced in tibial components of monoblock polyethylene design, as there is no backside wear. We investigated the effect...

متن کامل

Surface grafting of biocompatible phospholipid polymer MPC provides wear resistance of tibial polyethylene insert in artificial knee joints.

OBJECTIVE Aseptic loosening of artificial knee joints induced by wear particles from a tibial polyethylene (PE) insert is a serious problem limiting their longevity. This study investigated the effects of grafting with our original biocompatible phospholipid polymer 2-methacryloyloxyethyl phosphorylcholine (MPC) on the insert surface. METHODS The hydrophilicity of the PE surface was determine...

متن کامل

Traumatic Dislodgement of Tibial Polyethylene Insert after a High-Flex Posterior-Stabilized Total Knee Replacement

Many pathologic entities can produce a painful total knee replacement (TKR) that may lead to potential prosthetic failure. Polyethylene insert dissociation from the tibial baseplate has been described most frequently after mobile-bearing and cruciate-retaining TKRs. However, only 3 tibial insert dislocations in primary fixed-bearing High-Flex posterior-stabilized TKRs have been reported. We pre...

متن کامل

Eleven-year implant survival rates of the all-polyethylene and metal-backed modular Optetrak posterior stabilized knee in bilateral simultaneous cases.

A prospective randomized study was conducted to determine if a design change in the articular surface geometry introduced in the Optetrak total knee to increase prosthetic joint conformity and further reduce polyethylene stress had any impact on implant survival, particularly when the all-polyethylene version of the implant was used. Forty-seven patients undergoing bilateral simultaneous total ...

متن کامل

Polyethylene Backside Damage and Insert Micromotion in Total Knee Arthroplasty:does the Locking Mechanism Degrade with Time?

Introduction: It has been suggested that the capture mechanism of modular polyethylene tibial inserts degrades with time in-situ.[2] However, a significant correlation between insert micromotion and insitu time has not been reported. While it is intuitive that greater micromotion would result in greater backside damage, there are few data from autopsy retrievals to support this point and large ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the mechanical behavior of biomedical materials

دوره 38  شماره 

صفحات  -

تاریخ انتشار 2014