Design of Mouse Pad Monitoring Heart Rate and Bloody Oxygen Saturation Based on Microcontroller Control Unit

نویسندگان

  • Yingzhi Wang
  • Dong Pu
  • Jia Yang
  • Tailin Han
چکیده

Heart rate and bloody oxygen saturation are significant human's health parameters. This design is a mouse pad monitoring heart rate and oxygen saturation, to reduce the risk of undetected heart state change after concentrating on computer for a long time. Optical power signals reflected by blood are collected by reflective photoelectric sensor, NJL5501R, and then through filtering and amplification of integrated analog front end, AFE4490, are collected by MCU, STM32F103.The MCU calculates out the values of P-P interval, heart rate (HR) and bloody oxygen saturation (BOS) and transmits them to upper computer via USB or smart phone via Bluetooth, resulting in real-time monitoring heart state. The experiment shows the accuracy of this mouse pad: P-P interval±10ms, HR±1 and BOS±3%, and human's health situation can be indicated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Real-Time Health Monitoring System on Wireless Sensor Network

In this work, a portable real-time wireless health monitoring system is developed. The system is used for remote monitoring of patients’ heart rate and oxygen saturation in blood. The system was designed and implemented using ZigBee wireless technologies. All pulse oximetry data are transferred within a group of wireless personal area network (WPAN) to database computer server. The sensor modul...

متن کامل

تأثیر ساکشن لوله داخل نای بر وضعیت همودینامیک واکسیژناسیون خون شریانی

  Background and Aim: Intratracheal suctioning is a standard method of nursing care for intubated patients with the aim of cleaning airway for good oxygenation. The aim of this study was to evaluate the effects of intratracheal suctioning on blood pressure, heart rate, and arterial oxygen saturation.   Materials and Methods: This was a semi-experimental research in which the patients admitted t...

متن کامل

Online Graphical Display of Blood Oxygen Saturation and Pulse Rate

This paper will design a non-invasive pulse oximeter using the ADuC842 microcontroller. A pulse oximeter is a medical device that indirectly monitors the oxygen saturation of a patient's blood and heart rate. The hardware has been developed for the pulse oximeter and programming/coding has been done for calculating blood oxygen saturation and pulse rate of a patient. The results are displayed o...

متن کامل

Capstone Design 14:332:468 A Wearable Pulse Oximeter

In this report, the design and implementation of a low-cost, portable and wearable pulse oximeter is presented. A pulse oximeter is a non-invasive device capable of monitoring the blood’s oxygen saturation. It has been widely used in the medical, fitness and clinical care worlds. A low-cost wearable oximeter can significantly expand its applicability. The goal of this capstone design project wa...

متن کامل

Clinical Predictors of Intensive Care Unit Admission for Asthmatic Children

IntroductionChildren with severe asthma attack are a challenging group of patients who could be difficult to treat and leading to significant morbidity and mortality. Asthma attack severity is qualitatively estimated as mild, moderate and severe attacks and respiratory failure based on conditions such as respiration status, feeling of dyspnea, and the degree of unconsciousness. part of which ar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015