The effect of nitrous oxide on the measurement of single-breath transfer factor.

نویسندگان

  • C L Phillips
  • R Simmul
  • A I Smith
  • N Berend
چکیده

One hour after a bone marrow biopsy and inhalation of Entonox gas (50% nitrous oxide (N2O) and 50% oxygen), a patient had a markedly reduced transfer factor of the lung for carbon monoxide (TL,CO). Three hours after Entonox, the patient had a normal TL,CO. Since carbon monoxide (CO) and N2O have similar spectral wavelengths, it was proposed that residual N2O in the lungs was interfering with the infra-red analysers used to detect CO concentrations. Experiments were performed to verify the "interference" effect and its duration. Five healthy volunteers performed serial triplicate TL,CO measurements over 3 h on two randomized days (Control vs N2O). The first triplicate TL,CO on each day served as a baseline measurement. Following the baseline measurement on the N2O day, each subject inhaled Entonox for 10 min. To serve as a control for the infrared effect, the identical protocol was repeated using a gas chromatography method for TL,CO determination. The infra-red method showed a marked reduction (> 50%) in TL,CO 30 min after N2O inhalation. This reduction did not return to baseline levels for at least 2 h. In comparison, the gas chromatography method showed no significant reduction in TL,CO. In a group of healthy nonsmoking subjects, N2O markedly affected the measurement of the transfer factor of the lungs for carbon monoxide using infra-red analysers. The time course over which the measurement was reduced was at least 2 h for a 10 min inhalation period. The effect was entirely due to a measurement error associated with infra-red technology.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه روش های اینداکشن استنشاقی Single breath inhalation و Tidal volume technique با اینداکشن وریدی (نسدونال، ساکسینیل)، دانشگاه علوم پزشکی تهران، 1379

The induction characteristic of halothane in nitrous oxide and oxygen were compared with halothane in oxygen alone and intravenous induction with thiopentum and succinylcholine.Materials and Methods: A vital capacity technique was used for the gaseous induction groups using a mapleson F system and a 1-litre reservoir bag. four end points of anesthesia were recorded: time to cessation of hand gr...

متن کامل

DFT Study of Nitrous Oxide Adsorption on the Surface of Pt-Decorated Graphene

In the present study we search potential of Pt-decorated graphene (PtG) as a new nanostructure adsorbent for nitrous oxide (N2O) using density functional theory (DFT). After fully relaxation of different possible orientations of N2O-PtG complex, we distinguished two optimized configurations for this system; 1- terminal N-side of gas is oriented towards Pt so that the molec...

متن کامل

P110: Nitrous Oxide and Neuroinflammation

Nitrous oxide was an anaesthetic gas that was used for many years. There were many anaesthetic drugs in operations  with many side effects. Nitrous oxide had some side effects too. But it was a safe gas in many times. In hospital personnel who worked in operating rooms exposure to this gas was important. The objective of this study was the introduction of nitrous oxide and neurologic side ...

متن کامل

Solubility characteristics of the ideal agent for measurement of cardiac output by soluble gas uptake methods.

Measurements of the rate of uptake of soluble gases such as nitrous oxide or acetylene has been used as the basis of a method of cardiac output estimation since 1912. Using theoretical models of single, multiple and rebreathing techniques of cardiac output measurement, we determined the effect of solubility in blood and lung tissue on the changes in the final expired concentration of the gas. D...

متن کامل

Investigation of nanoparticles diameter on free convection of Aluminum Oxide-Water nanofluid by single phase and two phase models

In this research, effect of nanoparticles dimeter on free convection of aluminum oxide-water was investigated in a cavity by single phase and two phase models. The range of Rayleigh number is considered 105-107 in volume fractions of 0.01 to 0.03 for nanoparticles with various diameters (25, 33, 50 and 100 nm). Given that the two phase nature of nanofluids, necessity of modeling by this method ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 10 1  شماره 

صفحات  -

تاریخ انتشار 1997