Effect of the pilot hole preparation on the anchorage of pedicle screws

نویسندگان

  • Gustavo Silva Abrahão
  • Rodrigo César Rosa
  • Rodrigo Okubo
  • Antônio Carlos Shimano
چکیده

OBJECTIVE We evaluated the influence of the diameter and the preparation of the pilot hole on the resistance to the pulling out and the strength when inserting pedicle screws with conical internal diameter. METHODS Mechanical experiments were performed with pedicle conical screws of 4.2 mm and 5.2 mm diameter. They were inserted in the vertebral pedicles of swine. The hole was manufactured with a drill and probes with different diameters. RESULTS While testing the 4.2 mm screw, the perforation of holes with measure equal or inferior to the lesser internal diameter of the screw increased the torque and the resistance to pull-out strength. Perforations with different instruments have presented similar results. Perforations with probes allowed the holes manufactured with dimensions superior to the lesser internal diameter of the screw to show similar resistance to that of the perforations with dimensions equal to the lesser internal diameter of the implant, made with probes and drills. CONCLUSION For 4.2 mm screws, the diameter and the preparation of the hole influence the torque and the resistance. For 5.2 mm screws, there is only influence on the insertion torque. There is no correlation between pulling out strength and insertion torque. Level of Evidence II, Therapeutic Studies - Investigating the Results of Treatment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Pilot Hole Tapping on Pullout Strength and Insertion Torque of Dual Core Pedicle Screws.

OBJECTIVE To evaluate the influence of pilot hole tapping on pullout resistance and insertion torque of pedicle screws with a conical core. METHODS Mechanical tests using a universal testing machine were performed on pedicle screws with a conical core that were inserted into pedicles in the fifth lumbar vertebra of calves. The insertion torque was measured using a torque meter with a capacity...

متن کامل

Biomechanical Performance of an Injectable Screw for Fixation in Severely Osteoporotic Bone: an Experimental Study

INTRODUCTION Pedicle screw fixation in a severely osteoporotic spine remains a challenge for orthopaedic surgeons. Previous studies have demonstrated that pedicle screw fixation is highly correlated to the bone mineral density [1], and increasing the screw’s pullout strength can be achieved using a variety of methods, these include the use of pedicle screws with various designs [2,3]. However, ...

متن کامل

Pedicle Screw Fixation Study in Immature Porcine Spines to Improve Pullout Resistance during Animal Testing

The porcine model is frequently used during development and validation of new spinal devices, because of its likeness to the human spine. These spinal devices are frequently composed of pedicle screws with a reputation for stable fixation but which can suffer pullouts during preclinical implantation on young animals, leading to high morbidity. With a view to identifying the best choices to opti...

متن کامل

Molar Uprighting Using Mini-Screws after Distalization by the Pendulum Appliance: A Case Report

A 16-year-old Class II female patient was treated without tooth extraction. The upper first molars were distalized by the Pendulum appliance. After six months, the molars tipped significantly to the distal. To correct this side effect, we decided to upright the molars using skeletal anchorage. On each side, a mini-screw was inserted between first and second premolars in the buccal cortical plat...

متن کامل

Evaluation of insertion torque of different orthodontic miniscrews: An in vitro study

*Department of P.O.P, college of dentistry, university of Mosul, Mosul, Iraq. Introduction Conservation of anchorage in totality has been a perennial problem to the traditional orthodontist. Conventional means of supporting anchorage have been used by either intra oral sites or relying on extra oral means. Both of these have their limitations. The extra oral forces very difficult device and som...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 20  شماره 

صفحات  -

تاریخ انتشار 2012