The introduction of bromocresol purple for the determination of serum albumin on SMAC and ACA, and the standardization procedure.

نویسندگان

  • H A Assink
  • B G Blijenberg
  • G J Boerma
  • B Leijnse
چکیده

The bromocresol purple methods for the determination of serum albumin on the Technicon SMAC and the DuPont ACA systems were evaluated and compared with the corresponding bromocresol green methods, a radial immunodiffusion (RID) and an electrophoresis technique. The linearity and precision of the dye binding methods were comparable. The bromocresol purple methods were more influenced by lipaemia and to a lesser extent by high bilirubin concentrations. The specificity of the bromocresol purple methods was superior to that of the bromocresol green methods and showed excellent correlations with the radial immunodiffusion method: bromocresol purple: SMAC = 1.03 (RID) + 0.32; bromocresol purple: ACA = 1.00 (RID) + 1.27. The bromocresol purple methods intercorrelated better than the bromocresol green methods. Freeze-dried sera can be used for albumin standardization. Analysis of the albumin fractions of freeze-dried and liquid sera by high-performance liquid chromatography (HPLC) did not reveal significant differences in albumin polymerization. Purified albumin reacted, irrespective of the degree of polymerization, very differently in the dye-binding methods. The bromocresol purple methods showed an overestimation of purified albumin, the bromocresol green methods an underestimation. The reason for these differences is unclear. Non-human albumin reacted poorly with bromocresol purple in contrast with bromocresol green.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spectrophotometric Methods for Determination of Sunitinib in Pharmaceutical Dosage Forms Based on Ion-pair Complex Formation

Three rapid spectrophotometric methods were developed for the determination of sunitinib based on the formation of ion-pair complex in acidic medium with bromocresol purple, bromothymol blue, and bromophenol blue. The formed ion-pair complexes, extractable with chloroform, were measured at 422 nm for bromocresol purple, 425 nm for bromothymol blue and 427 nm for bromophenol blue. All these meth...

متن کامل

Bromocresol purple, a non-specific colour reagent for the determination of serum albumin.

The determination of serum albumin with the dye reagent bromocresol purple was investigated. We found that bromocresol purple is not a specific reagent for albumin, but that serum proteins in the alpha-, beta-, and gamma-globulin fractions also react with this dye. Similar results were obtained for bromocresol green. Furthermore there is a great difference in absorbance between human and bovine...

متن کامل

Spectrophotometric Methods for Determination of Sunitinib in Pharmaceutical Dosage Forms Based on Ion-pair Complex Formation

Three rapid spectrophotometric methods were developed for the determination of sunitinib based on the formation of ion-pair complex in acidic medium with bromocresol purple, bromothymol blue, and bromophenol blue. The formed ion-pair complexes, extractable with chloroform, were measured at 422 nm for bromocresol purple, 425 nm for bromothymol blue and 427 nm for bromophenol blue. All these meth...

متن کامل

Biol. Pharm. Bull. 30(7) 1187—1190 (2007)

cells, proteins, and small molecules from the alveolar space of the lower respiratory tract since the first report of Reynolds and Newball over three decades ago. The analysis of these components is of wide diagnostic and investigative value. In bronchoalveolar lavage, sterile saline is administered into the bronchoalveolar space and aspirated by syringe. Because recovery of the components in b...

متن کامل

Measurement of serum albumin by capillary zone electrophoresis, bromocresol green, bromocresol purple, and immunoassay methods.

BACKGROUND/AIMS The introduction of capillary zone electrophoresis (CZE) to this laboratory has highlighted discrepancies in albumin measured on an Abbott Aeroset by bromocresol green (BCG) and that calculated by CZE on the basis of total protein measured by Biuret. METHODS This study examined differences in albumin estimation by CZE, Abbott Aeroset BCG, and Aeroset bromocresol purple (BCP), ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie

دوره 22 10  شماره 

صفحات  -

تاریخ انتشار 1984