Accuracy of physical activity monitors in pregnant women.

نویسندگان

  • Christopher P Connolly
  • Dawn P Coe
  • Jo M Kendrick
  • David R Bassett
  • Dixie L Thompson
چکیده

PURPOSE To determine the step count accuracy of three pedometers and one accelerometer in pregnant women during treadmill walking. METHODS Participants were 30 women in the second or third trimester (20-34 wk) who were screened for pregnancy-related risk factors. Each participant was fitted with a belt containing three physical activity monitors: Yamax Digiwalker SW-200 (DW), New Lifestyles NL 2000 (NL), and GT3X ActiGraph accelerometer (ACT). The Omron HJ-720ITC (HJ) was placed in the pants' front pocket. Participants walked at 54, 67, 80, and 94 m · min for 2 min each. Actual steps were determined by an investigator using a hand-tally counter. The mean percent of steps recorded was calculated for each device at each speed and compared. Pearson correlations were used to determine the effect of body mass index and tilt angle on pedometer accuracy. RESULTS There was a significant interaction between speed and device (F9,20 = 7.574, P < 0.001). Across all speeds, the NL and HJ had the lowest error. The ACT and DW underestimated the actual steps taken, particularly at the slower walking speeds. At 54 m · min, the ACT averaged 77.5% of steps and the DW averaged 56.9% of steps. Significant differences in the mean percent of steps recorded were found between devices at all speeds. Body mass index was only significantly correlated with percent of steps recorded by the NL, and there were no significant correlations between steps recorded and tilt angle. CONCLUSIONS In pregnant women, the ACT and DW had more error than the NL and HJ. On the basis of these results, the NL and HJ should be considered for use in further research studies and physical activity programs that focus on walking during pregnancy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Sleep Quality in Athlete and Non-Athlete Pregnant Women

Background: Recent studies have shown that physical activity is an effective factor in improving sleep quality. Therefore, this study aimed to compare the sleep quality of athlete and non-athlete pregnant women. Methods: This cross-sectional descriptive analytical study was performed on 300 pregnant women in the last trimester of pregnancy, referred to prenatal care unit of Amiralmomenin Hos...

متن کامل

Objectively assessing treadmill walking during the second and third pregnancy trimesters.

BACKGROUND To effectively promote physical activity (PA) and quantify the effects of PA interventions for pregnant women, PA measurement during pregnancy needs improvement. The purpose of this study was to assess PA monitor output during a controlled, treadmill walking protocol among pregnant women at 20- and 32-weeks gestation. METHODS Women (N = 43) wore an Actigraph accelerometer, NL1000, ...

متن کامل

The Relationship between Cognitive Social Theory and Physical Activity in Pregnant Women

BackgroundAlthough following a suitable sports program with mild intensity promoted the health of mother's who had healthy pregnancy and caused no harm to the growing fetus; pregnant women usually choose to live a sedentary life. This study was conducted to determine the psychological factors related to physical activity in pregnant women. Materials and MethodsThis descriptive, correlational an...

متن کامل

The Effect of Trans Theoretical Model (TTM) on Exercise Behavior in Pregnant Women Referred to Dehaghan Rural Health Center in

Introduction: Despite numerous benefits of physical activity during pregnancy, it's not common in women, probably due to knowledge deficiency. This study aimed to assess the effect of Trance Theoretical Model (TTM) on physical activity in pregnant women. Methods: In a quasi-experimental study, 100 women referred to Dehaghan health centers in year 2010 were randomly assigned to control and expe...

متن کامل

Agreement between pedometer and accelerometer in measuring physical activity in overweight and obese pregnant women

BACKGROUND Inexpensive, reliable objective methods are needed to measure physical activity (PA) in large scale trials. This study compared the number of pedometer step counts with accelerometer data in pregnant women in free-living conditions to assess agreement between these measures. METHODS Pregnant women (n = 58) with body mass index ≥25 kg/m(2) at median 13 weeks' gestation wore a GT1M A...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medicine and science in sports and exercise

دوره 43 6  شماره 

صفحات  -

تاریخ انتشار 2011