Validity of diagnostic computer-based air and forehead bone conduction audiometry.
نویسندگان
چکیده
Computer-based audiometry allows for novel applications, including remote testing and automation, that may improve the accessibility and efficiency of hearing assessment in various clinical and occupational health settings. This study describes the validity of computer-based, diagnostic air and forehead bone conduction audiometry when compared wtih conventional industry standard audiometry in a sound booth environment. A sample of 30 subjects (19 to 77 years of age) was assessed with computer-based (KUDUwave 5000) and industry standard conventional audiometers (GSI 61) to compare air and bone conduction thresholds and test-retest reliability. Air conduction thresholds for the two audiometers corresponded within 5 dB or less in more than 90% of instances, with an average absolute difference of 3.5 dB (3.8 SD) and a 95% confidence interval of 2.6 to 4.5 dB. Bone conduction thresholds for the two audiometers corresponded within 10 dB or less in 92% of instances, with an average absolute difference of 4.9 dB (4.9 SD) and a 95% confidence interval of 3.6 to 6.1 dB. The average absolute test-retest threshold difference for bone conduction on the industry standard audiometer was 5.1 dB (5.3 SD) and for the computer-based audiometer 7.1 dB (6.4 SD). Computer-based audiometry provided air and bone conduction thresholds within the test-retest reliability limits of industry standard audiometry.
منابع مشابه
Pure-tone audiometry outside a sound booth using earphone attentuation, integrated noise monitoring, and automation.
OBJECTIVE Accessibility of audiometry is hindered by the cost of sound booths and shortage of hearing health personnel. This study investigated the validity of an automated mobile diagnostic audiometer with increased attenuation and real-time noise monitoring for clinical testing outside a sound booth. DESIGN Attenuation characteristics and reference ambient noise levels for the computer-base...
متن کاملValidity of diagnostic pure-tone audiometry without a sound-treated environment in older adults.
OBJECTIVE To investigate the validity of diagnostic pure-tone audiometry in a natural environment using a computer-operated audiometer with insert earphones covered by circumaural earcups incorporating real-time monitoring of environmental noise. DESIGN A within-subject repeated measures design was employed to compare air (250 to 8000 Hz) and bone (250 to 4000 Hz) conduction pure-tone thresho...
متن کاملDistribution Characteristics of Air-Bone Gaps: Evidence of Bias in Manual Audiometry.
OBJECTIVES Five databases were mined to examine distributions of air-bone gaps obtained by automated and manual audiometry. Differences in distribution characteristics were examined for evidence of influences unrelated to the audibility of test signals. DESIGN The databases provided air- and bone-conduction thresholds that permitted examination of air-bone gap distributions that were free of ...
متن کاملIdentification of conductive hearing loss using air conduction tests alone: reliability and validity of an automatic test battery.
OBJECTIVES The primary objective of this study was to determine whether a combination of automatically administered pure-tone audiometry and a tone-in-noise detection task, both delivered via an air conduction (AC) pathway, could reliably and validly predict the presence of a conductive component to the hearing loss. The authors hypothesized that performance on the battery of tests would vary a...
متن کاملValidity of Automated Threshold Audiometry: A Systematic Review and Meta-Analysis.
OBJECTIVES:: A systematic literature review and meta-analysis on the validity (test-retest reliability and accuracy) of automated threshold audiometry compared with the gold standard of manual threshold audiometry was conducted. DESIGN:: A systematic literature review was completed in peer-reviewed databases on automated compared with manual threshold audiometry. Subsequently a meta-analysis wa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of occupational and environmental hygiene
دوره 8 4 شماره
صفحات -
تاریخ انتشار 2011