Quantitative assessment of effects of phase aberration and noise on high-frame-rate imaging.
نویسندگان
چکیده
The goal of this paper is to quantitatively study effects of phase aberration and noise on high-frame-rate (HFR) imaging using a set of traditional and new parameters. These parameters include the traditional -6-dB lateral resolution, and new parameters called the energy ratio (ER) and the sidelobe ratio (SR). ER is the ratio between the total energy of sidelobe and the total energy of mainlobe of a point spread function (PSF) of an imaging system. SR is the ratio between the peak value of the sidelobe and the peak value of the mainlobe of the PSF. In the paper, both simulation and experiment are conducted for a quantitative assessment and comparison of the effects of phase aberration and noise on the HFR and the conventional delay-and-sum (D&S) imaging methods with the set of parameters. In the HFR imaging method, steered plane waves (SPWs) and limited-diffraction beams (LDBs) are used in transmission, and received signals are processed with the Fast Fourier Transform to reconstruct images. In the D&S imaging method, beams focused at a fixed depth are used in transmission and dynamically focused beams are used in reception for image reconstruction. The simulation results show that the average differences between the -6-dB lateral beam widths of the HFR imaging and the D&S imaging methods are -0.1337mm for SPW and -0.1481mm for LDB, which means that the HFR imaging method has a higher lateral image resolution than the D&S imaging method since the values are negative. In experiments, the average differences are also negative, i.e., -0.2804mm for SPW and -0.3365mm for LDB. The results for the changes of ER and SR between the HFR and the D&S imaging methods have negative values, too. After introducing phase aberration and noise, both simulations and experiments show that the HFR imaging method has also less change in the -6-dB lateral resolution, ER, and SR as compared to the conventional D&S imaging method. This means that the HFR imaging method is less sensitive to the phase aberration and noise. Based on the study of the new parameters on the HFR and the D&S imaging methods, it is expected that the new parameters can also be applied to assess quality of other imaging methods.
منابع مشابه
Effects of phase aberration on high frame rate imaging.
A high frame-rate (HFR) imaging method (about 3750 frames/s for imaging of biological soft tissues at a depth of 200 mm) has been developed recently with limited diffraction beams. This method uses the fast Fourier transform (FFT) and inverse fast Fourier transform (IFFT) to construct images, and can be implemented with simple and inexpensive hardware, compared to the conventional delay-and-sum...
متن کاملEffects of optimized photorefractive keratectomy (PRK) operation on the asphericity and high-order aberration changes
Background: Optimized is a common and important method in which aberrations are created by the device and the surgeon, but high-grade aberrations are out of the surgeon's control and are induced by the device in the patient. The aim of this study was the evaluation of out-of-control high-order aberration changes before and after PRK surgery and these impact on vision outcome. Materials and meth...
متن کاملAssessment of the Wavelet Transform for Noise Reduction in Simulated PET Images
Introduction: An efficient method of tomographic imaging in nuclear medicine is positron emission tomography (PET). Compared to SPECT, PET has the advantages of higher levels of sensitivity, spatial resolution and more accurate quantification. However, high noise levels in the image limit its diagnostic utility. Noise removal in nuclear medicine is traditionally based on Fourier decomposition o...
متن کاملEvaluation of the potential impact of reconstruction method on dyssynchrony parameters derived by phase analysis of gated-SPECT MPI: Comparison of two quantitative software
Introduction: Gated SPECT myocardial perfusion scanning has new capabilities in addition to its main applications such as left ventricular dyssynchrony using phase analysis. Phase analysis has been investigated through various software including Emory Cardiac Toolbox (ECTb) and Quantitative Gated SPECT (QGS). The aim of this study is to evaluate the effect of reconstruction par...
متن کاملQuantitative Assessment of Conventional and Modern De-Noising on Nuclear Medicine Images
Introduction: One of the major problems in the development of nuclear medicine images is the presence of noise. The noise level in nuclear medicine images is usually reduced by the analysis of imaging data in a Fourier transform environment. The main drawback of this environment belongs to low signal to noise ratio in high frequencies because removing noise frequencies may remove data and times...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ultrasonics
دوره 53 1 شماره
صفحات -
تاریخ انتشار 2013