In Vivo Positional Analysis of Implantable Collamer Lens Using Ultrasound Biomicroscopy

نویسندگان

  • Ahmed Mohamed Kamal Elshafei
  • Mahmoud Mohamed Genaidy
  • Hossam Mohamed Moharram
چکیده

Purpose. To evaluate the anterior segment, the anatomical position of the implantable collamer lenses (ICL), and its relationship to adjacent ocular structures using Ultrasound Biomicroscopy (UBM). Methods. In a prospective study, 142 myopic eyes of 93 patients implanted with Visian ICL were subjected to UBM examination between March 2010 and January 2015. The relative position of ICL to the adjacent structure and the overall iris configuration were evaluated. The machine calibers were used to measure the minimum central distance between the ICL and anterior lens capsule (vault) and the vertical central distance between the corneal endothelium and the ICL (E-ICL). Results. The mean ICL vault was 376 ± 105 μm. The mean E-ICL was 2826 ± 331 μm. Contact between ICL and the posterior epithelium of the iris was present in all eyes. The overall iris configuration was flat in 89 eyes. Central anterior convexity was present in 41 eyes and mild peripheral iris bombe in 12 eyes. The haptics could be imaged in the ciliary sulcus in 112 eyes and at least one haptic resting on the lens periphery and zonules in 30 eyes. Conclusion. UBM can provide valuable anatomical information that allows detailed postoperative in vivo assessment of ICL.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microbial contamination of ultrasound biomicroscopy probes: evaluation of cross-infection risk.

Ultrasound biomicroscopy (UBM) is being used increasingly in cataract and refractive surgery to evaluate phacomorphic lenses, dislocated intraocular lenses, misplaced haptics, sulcus-to-sulcus measurements for implantable Collamer lenses (ICLs), ciliary body cysts before ICL implantation, retained lens fragments, and anterior effusions. In a previous report, biometry apparatus grew pathogenic f...

متن کامل

Accommodation after an implantable collamer lens implantation in high myopia patients

Purpose: The purpose of the current study was to investigate the pathogenesis of visual fatigue in patients after implantable collamer lens (ICL) implantation based on an evaluation of accommodation function. Methods: Thirty patients (12 males and 18 females) with high myopia underwent a toric or non-toric ICL procedure. Accommodation function was tested pre-operatively and 1, 3, and 6 months p...

متن کامل

Acetazolamide-induced bilateral choroidal effusion following insertion of a phakic implantable collamer lens.

PURPOSE To present the case of a 28-year-old man with acetazolamide-induced bilateral choroidal effusion after uneventful surgery of the second eye in delayed sequential bilateral insertion of an implantable collamer lens for hyperopia. METHODS Case report. RESULTS Surgery of the left eye was uneventful, and the implantable collamer lens was implanted 3 weeks later in the right eye. Twenty-...

متن کامل

Implantation of an implantable collamer lens and iris cerclage for the treatment of Urrets-Zavalia syndrome

A 27-year-old woman with bilateral high myopia had anterior chamber iris-claw phakic intraocular lens implantation in her left eye under local anesthesia and with no intraoperative complications. The preoperative slit-lamp examination was normal, and she had no relevant past medical history. On the second postoperative day, patient developed fixed, dilated mydriasis, and one month later, an IOL...

متن کامل

Improving accuracy of phakic intraocular lens sizing using high-frequency ultrasound biomicroscopy.

PURPOSE To assess the efficacy of high-frequency ultrasound biomicroscopy (UBM) in improving the accuracy of phakic intraocular lens (pIOL) sizing by increasing the incidence of acceptable postoperative vault. SETTING Multiple private practices, United States. DESIGN Evaluation of diagnostic test or technology. METHODS This prospective multicenter clinical study evaluated eyes having pIOL...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2016  شماره 

صفحات  -

تاریخ انتشار 2016