Kinetic enzymic assay for D(-)-lactate, with use of a centrifugal analyzer.

نویسندگان

  • C W Ludvigsen
  • J R Thurn
  • G L Pierpont
  • J H Eckfeldt
چکیده

The D(-) isomer of lactic acid appears to cause a form of metabolic encephalopathy experienced by patients who have had jejunoileal bypass for morbid obesity. However, analysis for D(-)-lactate is not routinely available in clinical or reference laboratories. We describe an enzymic centrifugal-analyzer assay for D(-)-lactate in plasma or serum, with use of D(-)-lactate dehydrogenase. The method involves two-point kinetic calibration and preincubation of specimen and NAD+, thus eliminating the need for specimen-blanking or protein-precipitating pretreatment. This rapid, accurate, and precise assay should be helpful in evaluating patients with "short-bowel syndrome" who display confusion, lethargy, ataxia, or other central nervous-system disturbances that may be ascribable to D(-)-lactic acidosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An enzymic, reaction-rate assay for serum creatinine with a centrifugal analyzer.

We describe a procedure for specific, rapid, kinetic determination of creatinine, in which a manual coupled-enzyme micro-scale assay is adapted to a centrifugal analyzer. The creatinine reaction is ultimately linked to NADH utilization, which is measured by the absorbance change at 340 nm. This procedure requires 15 microL of serum and the standard curve is linear to a creatinine concentration ...

متن کامل

Fixed-time kinetic assay of plasma ammonia, with NADPH as cofactor, with a centrifugal analyzer.

We describe a fixed-time, enzymatic, reaction-rate procedure for determining plasma ammonia with a centrifugal analyzer (Rotochem IIA/36; American Instrument Co., silver Spring, MD 20910), with NADPH as cofactor. The reaction is based on that of da Fonseca-Wollheim's modification [J. Clin. Chem. Clin. Biochem. 11, 421 (1973)] of the Kirstein reaction, which depends on the catalytic amination of...

متن کامل

Stability in urea as a measure of cardiac lactate dehydrogenase on the centrifugal analyzer.

Kinetic methods are described for determination of total, heat-stable, and urea-stable lactate dehydrogenase (EC 1.1.1.27) activity on the centrifugal analyzer. In the urea-stable method we present, 2.6 molar urea is used to differentiate lactate dehydrogenase originatingfrom heart and liver.This urea concentration, greater than that used by most other investigators, better differentiates betwe...

متن کامل

Improved method for enzymatic determination of serum triglycerides.

I describe an enzymatic method for determing serum triglycerides (triacylglycerols). The triglycerides are hydrolyzed by a mixture of lipase and esterase. The glycerol released is determined by kinetic fixed-time analysis, with use of glycerol kinase, pyruvate kinase, and lactate dehydrogenase. Through addition of the competitive inhibitor ATP the Michaelis constant of pyruvate kinase is appare...

متن کامل

Kinetic measurement of total amylase and isoamylase activities with a centrifugal analyzer.

We evaluated a new kinetic assay for alpha-amylase (Phadebas IsoAmylase Test), using modified starch as the substrate and a CentrifiChem 400 centrifugal analyzer system. We determined isoamylase activities by using a selective inhibitor. Results were compared with those obtained with the chromogenic Phadebas dyed-starch technique. The method for total amylase appeared to be rapid and precise (C...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 29 10  شماره 

صفحات  -

تاریخ انتشار 1983