Hydraulic estimation of stenotic orifice area: a correction of the Gorlin formula.
نویسندگان
چکیده
To determine the source of errors in the Gorlin formula for estimating stenotic valvular orifice area, we used a pulsatile flow model that emulated left ventricular and aortic pressures and flow and allowed control of ventricular outflow orifice area. After comparing orifice areas calculated by the Gorlin formula with actual orifice areas, the Gorlin formula constant (k) was found to be highly correlated with the square root of the mean transvalvular gradient (r = .95). A new formula was derived empirically and predicted areas more accurately and with smaller standard errors than the Gorlin formula in the model (r = .98, SEE = 0.11 and r = .87, SEE = 0.28, respectively) in a series of 19 patients with Hancock porcine xenograft valves (r = .89, SEE = 0.07 and r = .60, SEE = 0.12, respectively) and in the original series of patients reported by Gorlin and Gorlin in proposing the Gorlin formula (r = .93, SEE = 0.11 and r = .91, SEE = 0.12, respectively).
منابع مشابه
DIAGNOSTIC METHODS VALVUIAR HEART DISEASE Hydraulic estimation of stenotic orifice area: a correction of the Gorlin formula
To determine the source of errors in the Gorlin formula for estimating stenotic valvular orifice area, we used a pulsatile flow model that emulated left ventricular and aortic pressures and flow and allowed control of ventricular outflow orifice area. After comparing orifice areas calculated by the Gorlin formula with actual orifice areas, the Gorlin formula constant (k) was found to be highly ...
متن کاملWhen should Doppler-determined valve area be better than the Gorlin formula?: Variation in hydraulic constants in low flow states.
In low flow states, underestimation errors occur when the Gorlin formula is used to calculate valve area. A model of valvular stenosis designed to examine changes in the hydraulic discharge coefficient (Cd) and coefficient of orifice contraction (Cc) may explain these errors. Unsteady flow was examined in a pulsatile pump model and in a dog model. Valve areas were calculated from pressure and f...
متن کاملMitral valve area in combined mitral stenosis and regurgitation.
Eight patients with mixed mitral stenosis and regurgitation underwent hemodynamic and angiographic study prior to mitral valve replacement. The stenotic orifice of the mitral valve was calculated employing the total left ventricular stroke volume by cineangiography as the numerator of the Gorlin Formula. Excellent agreement with the measured orifice of the mitral valve was obtained using a valu...
متن کاملA new non-invasive estimation of the stenotic aortic valve area by pulsed Doppler mapping.
A new pulsed Doppler mapping technique has been used to measure the severity of aortic valve stenosis. The Doppler examination was performed at the site of the aortic orifice in the parasternal short axis echocardiographic view and the method was based on the detection of the area of systolic flow through the stenotic orifice. This area was derived by planimetry and the measurements obtained by...
متن کاملDoppler Assessment of Prosthetic Valve Orifice Area
Background. Although Doppler echocardiography has been shown to be accurate in assessing stenotic orifice areas in native valves, its accuracy in evaluating the prosthetic valve orifice area remains undetermined. Methods and Results. Doppler-estimated valve areas were studied for their agreement with catheterderived Gorlin effective orifice areas and their flow dependence in five sizes (19/20-2...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 71 6 شماره
صفحات -
تاریخ انتشار 1985