Neointima development in externally stented saphenous vein grafts. External stents are bad for the patient: why not use an undamaged saphenous vein for coronary artery bypass graft?
نویسندگان
چکیده
Corresponding author: Michael R. Dashwood MD, PhD, Department of Surgery, University College London Medical School, Pond St, NW3 2QG London, United Kingdom, phone: +44 (0)20 7794 0500, e-mail: [email protected] Received: 11.01.2017, accepted: 23.01.2017. Neointima development in externally stented saphenous vein grafts. External stents are bad for the patient: why not use an undamaged saphenous vein for coronary artery bypass graft?
منابع مشابه
Neointima development in externally stented saphenous vein grafts. Progress in medicine is good for the patient: why not use total arterial revascularization?
Corresponding author: Przemysław Węglarz MD, 1 Department of Cardiology, Silesian University of Medicine, 45/47 Ziołowa St, 40-635 Katowice, Poland, phone: +48 600 467 332, e-mail: [email protected] Received: 23.01.2017, accepted: 13.02.2017. Neointima development in externally stented saphenous vein grafts. Progress in medicine is good for the patient: why not use total arterial revasculariza...
متن کاملMajor Leg Wound Complications After Saphenous Vein Harvest for Coronary Revascularization
Background: Major leg wound complications after coronary artery bypass graft procedures are infrequent and few are reported in the litrature.We present our experience in treating 30 patients with major leg wound complications after coronary revascularization procedures. Materials and Methods: A retrospective review of 2100 bypass procedures with saphenous veingraft performed over a 5-years p...
متن کاملNeointima development in externally stented saphenous vein grafts
INTRODUCTION The main limitation of coronary artery bypass grafting (CABG) is rapid neointimal hyperplasia leading to graft failure. AIM To assess plaque formation in saphenous vein grafts (SVG) covered by an external Dacron stent in comparison with the classical technique. MATERIAL AND METHODS In the study group vein grafts covered by external stent mesh made of Dacron were implanted. An i...
متن کاملAdministration of perivascular cyanoacrylate for the prevention of cellular damage in saphenous vein grafts: an experimental model
OBJECTIVE The saphenous vein is the most commonly used graft in coronary artery bypass surgery, since no suitable arterial graft is available. However, the frequency of late graft failure is a cause for research into graft protection. The objective of this study was to investigate the effect of synthetic adhesive cyanoacrylate administration on the saphenous vein graft for preventing vascular d...
متن کاملCoronary artery bypass grafting in diabetic patients: Should we still use the saphenous vein graft? A review of literature in the past 15 years
The burden of diseases associated with diabetes mellitus is dramatic: adults with diabetes mellitus are 2 to 4 times more likely to have cardiovascular diseases than those without it, and at least 65% will die because of diabetes complications. The revascularization strategy in these types of patients included percutaneous coronary interventions with bare metal stents or medicated stents and su...