Cardiac motion analysis to improve pacing site selection in CRT.

نویسندگان

  • Heng Huang
  • Li Shen
  • Rong Zhang
  • Fillia Makedon
  • Bruce Hettleman
  • Justin Pearlman
چکیده

RATIONALE AND OBJECTIVES The aim of the study is to build cardiac wall motion models to characterize mechanical dyssynchrony and predict pacing sites for the left ventricle of the heart in cardiac resynchronization therapy (CRT). MATERIALS AND METHODS Cardiac magnetic resonance imaging data from 20 patients are used, in which half have heart failure problems. We propose two spatio-temporal ventricular motion models to analyze the mechanical dyssynchrony of heart: radial motion series and wall motion series (a time series of radial length or wall thickness change). The hierarchical agglomerative clustering technique is applied to the motion series to find candidate pacing sites. All experiments are performed separately on each ventricular motion model to facilitate performance comparison among models. RESULTS The experimental results demonstrate that the proposed methods perform as well as we expect. Our techniques not only effectively generate the candidate pacing sites list that can help guide CRT, but also derive clustering results that can distinguish the heart conditions between patients and normals perfectly to help medical diagnosis and prognosis. After comparing the results between two different ventricular motion models, the wall motion series model shows a better performance. CONCLUSION In a traditional CRT device deployment, pacing sites are selected without efficient prediction, which runs the risk of suboptimal benefits. Our techniques can extract useful wall motion information from ventricular mechanical dyssynchrony and identify the candidate pacing sites with maximum contraction delay to assist pacemaker implantation in CRT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Septal flash predicts cardiac resynchronization therapy response in patients with permanent atrial fibrillation.

AIMS Patients with heart failure (HF) as well as atrial fibrillation (AF) have suboptimal response to cardiac resynchronization therapy (CRT). Identification of mechanical abnormalities, amenable to correction with CRT, might improve the selection of candidates and CRT efficiency. We evaluated whether abnormal septal motion, assessed by the presence of septal flash (SF) is related to CRT respon...

متن کامل

Three-dimensional mapping of optimal left ventricular pacing site for cardiac resynchronization.

BACKGROUND The efficacy of cardiac resynchronization therapy (CRT) depends on placement of the left ventricular lead within the late-activated territory. The geographic extent and 3-dimensional distribution of left ventricular (LV) locations yielding optimal CRT remain unknown. METHODS AND RESULTS Normal or tachypacing-induced failing canine hearts made dyssynchronous by right ventricular fre...

متن کامل

Optimal left ventricular endocardial pacing sites for cardiac resynchronization therapy in patients with ischemic cardiomyopathy.

OBJECTIVES We sought to investigate the impact of left ventricular (LV) pacing site on mechanical response to cardiac resynchronization therapy (CRT) in patients with ischemic cardiomyopathy (ICM). BACKGROUND CRT reduces morbidity and mortality in patients with dyssynchronous LV failure; however, variability in response, particularly in ICM patients, poses ongoing challenges. Endocardial bive...

متن کامل

Cardiac Resynchronization Therapy: The Remaining Challenges

Cardiac resynchronization therapy (CRT) has come a long way from its inception as a last-ditch attempt to salvage intractable heart failure (HF) in patients with demonstrated electrical dyssynchronies to its current status as a routine mainstream therapy recommended for moderate and even mild HF. The increase in popularity of CRT is due to two main factors: large-scale randomized clinical trial...

متن کامل

Prediction of response to cardiac resynchronization therapy using left ventricular pacing lead position and cardiovascular magnetic resonance derived wall motion patterns: a prospective cohort study

BACKGROUND Despite marked benefits in many heart failure patients, a considerable proportion of patients treated with cardiac resynchronization therapy (CRT) fail to respond appropriately. Recently, a "U-shaped" (type II) wall motion pattern identified by cardiovascular magnetic resonance (CMR) has been associated with improved CRT response compared to a homogenous (type I) wall motion pattern....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Academic radiology

دوره 13 9  شماره 

صفحات  -

تاریخ انتشار 2006