Practical Application of Quantitative HiSens Auto Rapid Plasma Reagin Latex Turbidimetric Immunoagglutination for Diagnosing Syphilis; Comparison Analysis between Rapid Plasma Reagin Latex Turbidimetric Immunoagglutination Test and Rapid Plasma Reagin Card Test
نویسندگان
چکیده
Background : The purpose of this study was to evaluate validity of quantitative RPR LTIA, HiSens Auto RPR LTIA (HBi Corp., South Korea) and to decide an adequate cutoff value for syphilis screening. Materials and Methods : A total of 549 serums or plasma specimens from patients were tested with RPR LTIA and RPR card tests. Degree of agreement between the two methods was analyzed, and validity of RPR LTIA test was analyzed by receiver operating characteristic (ROC) curves. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), accuracy, and ROC statistics of the RPR LTIA test were analyzed to decide an adequate cutoff value. Results : Agreement analysis showed slight to moderate agreement (k=0.093-0.588, P=0.000). Kappa value had its highest value at the cutoff value of 1.3 and 1.6 (k=0.588, P=0.000). Kappa value at the cutoff value of 1 ranked second (k=0.578. P=0.000). A plot of ROC curve showed a statistically valid result to differentiate between a syphilis test positive group and a syphilis test negative group (AUC=0.92, P=0.000). The cutoff values in RPR LTIA test ranged between 0.65 and 1.15 when both sensitivity and specificity were higher than 80%. Conclusion : HiSens Auto RPR LTIA test showed statistically valid result to differentiate between syphilis test groups. Considering the importance of sensitivity in screening for syphilis and the degree of agreement with RPR card test, the cutoff value of 1 in HiSens Auto RPR LTIA test is thought to be adequate.
منابع مشابه
Evaluation of NCS rapid plasma reagin card test, a new screening kit for syphilis.
Agreements in qualitative and quantitative test results between the recently marketed NCS rapid plasma reagin card test (NCS Diagnostics Corp.) and the Macro-Vue rapid plasma reagin 18-mm circle card test (Hynson, Westcott and Dunning) were 99.2 and 99.1%, respectively, indicating the NCS RPR card test to be an acceptable alternative procedure for the serodiagnosis of syphilis.
متن کاملFalse-positive reactions in the rapid plasma reagin-card, fluorescent treponemal antibody-absorbed, and hemagglutination treponemal syphilis serology tests.
Sera from 628 nonsyphilitic individuals were tested with the Rapid Plasma Reagin-Card, Fluorescent Treponemal Antibody-Absorbed, and Hemagglutination Treponemal Test for Syphilis tests to ascertain the comparative specificity of these tests. Many sera were also tested with the quantitative Venereal Disease Research Laboratory test. Sera included in the study were from both normal individuals an...
متن کاملComparison of a new rapid plasma reagin card test with the standard rapid plasma reagin 18-mm circle card test and the venereal disease research laboratory slide test for serodiagnosis of syphilis.
The rapid plasma reagin (RPR) card test manufactured by Beckman Instruments, Inc., was compared, qualitatively and quantitatively, with the Venereal Disease Research Laboratory (VDRL) slide test and the standard RPR 18-mm circle card tests for the serodiagnosis of syphilis. Sera from 638 individuals were used in this study. Two pilot lots and two production lots of antigen were submitted by Bec...
متن کاملEvaluation of a digital flocculation reader for the rapid plasma reagin test for the serological diagnosis of syphilis.
We described the ASiManager-AT digital flocculation reader to demonstrate concordance between visual and digital readings of the rapid plasma reagin test for detection of antibodies in the serum of patients with syphilis. A qualitative and quantitative rapid plasma reagin was performed on each serum samples giving a concordance of 98.6% and 99.7%, respectively, for reactives and 100% for nonrea...
متن کاملEvaluation of a new rapid plasma reagin card test as a screening test for syphilis.
This study evaluates the American Dade (Biokit Laboratories) rapid plasma reagin (Dade RPR) card test, currently used in Spain for the diagnosis of syphilis, which has been recently released to the U.S. market. Used as a basis for comparison with the Dade card test were the 18-mm standard rapid plasma reagin (standard RPR) card test and the Venereal Disease Research Laboratory (VDRL) slide test...
متن کامل