Swan-Ganz catheter-induced pulmonary artery pseudoaneurysm formation: three case reports and a review of the literature.
نویسندگان
چکیده
The use of Swan-Ganz catheters has increased tremendously since they were first introduced in 1970. Their ability to give vital hemodynamic measurements in critically ill patients makes their use invaluable when providing quality medical care. The formation of pulmonary artery (PA) pseudoaneurysm from a Swan-Ganz catheter-induced perforation of the PA is a rare but potentially fatal complication of Swan-Ganz catheter use. Three case presentations and a review of the literature are presented.
منابع مشابه
Endovascular treatment of PA pseudoaneurysm caused by Swan-Ganz catheter
The following case report describes a complication of Swan-Ganz catheterization and its endovascular treatment with a single coil. Application of this particular catheter in the pulmonary artery during cardiac surgery may lead to mechanical perforation and creation of an extravascular sac, which is called a pseudoaneurysm. There are different methods that lead to tamponade or closure of the lea...
متن کاملPulmonary artery rupture as a complication of Swan-Ganz catheter application. Diagnosis and endovascular treatment: a single centre's experience
INTRODUCTION The placement of a Swan-Ganz catheter into the pulmonary artery may lead to a number of complications (2-17%). In less than 0.2% of cases Swan-Ganz catheterization results in serious vascular damage - pulmonary artery rupture (PAR). This paper presents two distinct forms of iatrogenic PAR treated endovascularly using different vascular devices. AIM To evaluate the effectiveness o...
متن کاملCase Report Pulmonary Artery Catheter Complications: Report on a Case of a Knot Accident and Literature Review
A particular event concerning a Swan-Ganz catheter complication is reported. A 41-year-old woman was admitted at the emergency room of our hospital with massive gastrointestinal bleeding. A total gastrectomy was performed. During the postoperative period in the intensive care unit , the patient maintained hemodynamic instability. Invasive hemodynamic monitoring with a pulmonary artery catheter ...
متن کاملIsolated lower limb gangrene: a caveat of terlipressin therapy.
References: 1. Gidwani UK, Mohanty B, Chatterjee K: The pulmonary artery catheter: a critical reappraisal. Cardiol Clin 2013; 31: 545−65, viii. doi: 10.1016/j. ccl.2013.07.008. 2. Aggarwal N, Kupfer Y, Yoon TS, Tessler S: Pulmonary artery catheter coiled in the main pulmonary artery trunk. BMJ Case Rep 2013; 2013. doi: 10.1136/bcr-2013-200049. 3. Starzyk L, Yao E, Roche-Nagel G, Wasowicz M: Sna...
متن کاملVertebral arteriovenous fistula: an unusual complication of Swan-Ganz catheter insertion.
The leading causes of trauma to the major craniocerebral vessels include penetrating and non penetrating trauma [1 , 2]. Because the vertebral artery is confined to the incomplete bony canal formed by the successive foramina in the transverse processes of the upper cervical vertebrae, it is less susceptible to penetrating injury than is the carotid artery [2]. A review of the literature has unc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chest
دوره 120 6 شماره
صفحات -
تاریخ انتشار 2001