Comparison of surgical completeness between robotic total thyroidectomy versus open thyroidectomy.

نویسندگان

  • Kyung Tae
  • Chang M Song
  • Yong B Ji
  • Kyung R Kim
  • Ji Y Kim
  • Yun Y Choi
چکیده

OBJECTIVES/HYPOTHESIS The aim of this study was to investigate the surgical completeness of robotic total thyroidectomy compared with conventional open thyroidectomy. STUDY DESIGN Retrospective, case-control study. METHODS We studied 245 patients with papillary thyroid carcinoma who underwent total thyroidectomy and postoperative radioactive iodine (RAI) ablation. Of these, 62 patients underwent robotic thyroidectomy by a gasless unilateral axillo-breast (GUAB) or axillary (GUA) approach, and 183 underwent conventional open thyroidectomy. We analyzed serum TSH-stimulated thyroglobulin (Tg) and RAI uptake at the time of RAI remnant ablation to compare surgical completeness in the two groups. RESULTS Tumor characteristics and complications did not differ between the two groups except TNM stage. The mean TSH-stimulated Tg at the first RAI ablation was significantly higher in the robotic group (10.20 ± 9.98 ng/ml) than in the open group (3.85 ± 6.79 ng/ml) (P <0.001). In subgroup analysis of the robotic group by the period in which operations took place, TSH-stimulated Tg was significantly higher than in the open group in the first (13.28 ± 11.91 ng/ml) and second (10.45 ± 9.30 ng/ml) periods, but there was no significant difference in the third period (6.00 ± 6.26 ng/ml, P = 0.141). The RAI uptake rate at the first RAI ablation did not differ between the two groups, and TSH-stimulated Tg after RAI ablation was similar. CONCLUSION The surgical completeness of robotic total thyroidectomy by a GUAB/GUB approach is comparable to that of open thyroidectomy, if performed by experienced robotic thyroid surgeons in properly selected patients. LEVEL OF EVIDENCE 3b. Laryngoscope, 124:1042-1047, 2014.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Early surgical outcomes of robotic thyroidectomy by a gasless unilateral axillo-breast or axillary approach for papillary thyroid carcinoma: 2 years' experience.

BACKGROUND The efficacy of robotic thyroidectomy for thyroid cancer has not yet been assessed. The aim of this study was to evaluate the technical feasibility and completeness of robotic thyroidectomy for papillary thyroid carcinoma (PTC). METHODS We analyzed 75 patients with PTC who underwent robotic thyroidectomy from October 2008 to August 2010 using a gasless unilateral axillo-breast or a...

متن کامل

Robotic surgery for thyroid disease.

Robotic surgery is an innovation in thyroid surgery that may compensate for the drawbacks of conventional endoscopic surgery. A surgical robot provides strong advantages, including three-dimensional imaging, motion scaling, tremor elimination, and additional degrees of freedom. We review here recent adaptations, experience and applications of robotics in thyroid surgery. Robotic thyroid surgeri...

متن کامل

Comparative study of robotic versus endoscopic thyroidectomy by a gasless unilateral axillo-breast or axillary approach.

BACKGROUND Robotic thyroidectomy and conventional endoscopic thyroidectomy have not been thoroughly compared. In this study, we compared the potential advantages of robotic versus endoscopic thyroidectomy. METHODS We analyzed 218 consecutive patients who underwent endoscopic (105 cases) or robotic (113 cases) thyroidectomy using a gasless unilateral axillo-breast or gasless unilateral axillar...

متن کامل

A comparative study of postoperative pain for open thyroidectomy versus bilateral axillo-breast approach robotic thyroidectomy using a self-reporting application for iPad.

PURPOSE Postoperative pain for robotic thyroid surgeries including bilateral axillo-breast approach (BABA) has not been well studied. In this study, we have developed a self-reporting application (SRA) for iPad and prospectively collected pain scores from open thyroidectomy (OT) and BABA robotic thyroidectomy (RT) patients. METHODS Female patients who underwent total thyroidectomy for papilla...

متن کامل

Can Robotic Thyroidectomy Be Performed Safely in Thyroid Carcinoma Patients?

Since the adoption of the Da Vinci robotic system for remote access thyroid surgery, robotic thyroidectomy (RT) has become a popular surgical option for patients who want to avoid neck scars. Surgeons in South Korea pioneered this surgical technique and have reported successful outcomes. Although many studies have reported that RT is a feasible and safe therapeutic alternative, concerns over th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Laryngoscope

دوره 124 4  شماره 

صفحات  -

تاریخ انتشار 2014