BACKGROUND The objective of the study was to assess the time of exposure of the surgeon's hands to radiation and calculate of the equivalent dose absorbed during surgery of hand and wrist fractures with C-arm fluoroscope guidance. MATERIAL AND METHODS The necessary data specified by the objective of the study were acquired from operations of 287 patients with fractures of fingers, metacarpals, wrist bones and distal radius. 218 operations (78%) were percutaneous procedures and 60 (22%) were performed by open method. Data on the time of exposure and dose of radiation were acquired from the display of the fluoroscope, where they were automatically generated. These data were assigned to the individual patient, type of fracture, method of surgery and the operating surgeon. RESULTS Fixations of distal radial fractures required longer times of radiation exposure (mean 61 sec.) than fractures of the wrist/metacarpals and fingers (38 and 32 sec., respectively), which was associated with absorption of significantly higher equivalent doses. Fixations of distal radial fractures by open method were associated with statistically significantly higher equivalent doses (0.41 mSv) than percutaneous procedures (0.3 mSv). Fixations of wrist and metacarpal bone fractures by open method were associated with lower equivalent doses (0.34 mSv) than percutaneous procedures (0.37 mSv),but the difference was not significant. Fixations of finger fractures by open method were associated with lower equivalent doses (0.13 mSv) than percutaneous procedures (0.24 mSv), the difference being statistically non-significant. Statistically significant differences in exposure time and equivalent doses were noted between 4 surgeons participating in the study, but no definitive relationship was found between these parameters and surgeons' employment time. CONCLUSIONS 1. Hand surgery procedures under fluoroscopic guidance are associated with mild exposure of the surgeons' hands to radiation. 2. The equivalent dose was related to the type of fracture, operative technique and - to some degree - to the time of employment of the surgeon.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiation exposure of the surgeons in sentinel lymph node biopsy

Background: Sentinel node biopsy (SLNB) is the standard of care for breast cancer treatment and it is getting wide acceptance in Iran. The radiation safety of the procedure has been investigated under controlled conditions, but the standard dose of radiotracer and techniques are not always observed in the community setting. The aim of this study was to assess the magnitude of the absor...

متن کامل

Comprehensive TLD dosimetry of physicians and patients during interventional angiography procedures to estimate the risk of radiation deterministic effect

Introduction: Interventional angiography procedures are increasingly used today. These techniques require a long time of standing near the patient and x-ray tube which lead to increase the radiation-dose of the staff and interventionists. This may also, in turn, lead to the occurrence of radiation deterministic effects. Since a large number of interventional radiology were perf...

متن کامل

Radiation exposure of the hands and thyroid gland during percutaneous wiring of wrist and hand procedures.

The aim of this study was to investigate the radiation exposure of the hands and thyroid glands of orthopaedic surgeon and assistant during procedures involving percutaneous wiring of the hand and wrist. The radiation dose to the hand and thyroid glands was prospectively studied from a total of 30 percutaneous hand and wrist procedures. Four thermolucent densitometers were used to measure the r...

متن کامل

Surgeons' Exposure to Radiation in Single- and Multi-Level Minimally Invasive Transforaminal Lumbar Interbody Fusion; A Prospective Study

Although minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) has widely been developed in patients with lumbar diseases, surgeons risk exposure to fluoroscopic radiation. However, to date, there is no studies quantifying the effective dose during MIS-TLIF procedure, and the radiation dose distribution is still unclear. In this study, the surgeons' radiation doses at 5 places on...

متن کامل

Are Radiation Exposure Levels Used in Cardiology Dangerous?

Background: The number of interventional cardiology procedures performed has increased rapidly over the past years. While these procedures help physicians avoid using highly complicated invasive methods, it usually leads to high levels of exposure to ionizing radiation of both patients and cardiologist. The dose received by the cardiologist during interventional cardiology procedures is determi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ortopedia, traumatologia, rehabilitacja

دوره 16 6  شماره 

صفحات  -

تاریخ انتشار 2014