Hydroxyapatite ocular implant and non-integrated implants in eviscerated patients
نویسندگان
چکیده
INTRODUCTION This study compares the outcomes and complications of hydroxyapatite ocular implant and non-integrated ocular implants following evisceration. MATERIALS AND METHODS This is a retrospective study of 90 patients who underwent evisceration for different ocular affections, in the Ophthalmology Department of the University Emergency Hospital Bucharest, between January 2009 and December 2013. The outcomes measured were conjunctival dehiscence, socket infection, implant exposure and extrusion rate. RESULTS Forty-three patients had the hydroxyapatite implant (coralline-Integrated Ocular Implants, USA or synthetic-FCI, France) and forty-seven received non-integrated ocular implants (24 acrylic and 23 silicone). Five cases of socket infection, thirteen cases of extrusion and two cases of conjunctival dehiscence were encountered. CONCLUSIONS There was a higher rate of conjunctival dehiscence with hydroxyapatite ocular implant, but implant extrusion and socket infection were found in non-integrated ocular implants.
منابع مشابه
Topographic measurements of eyelids and orbit in enucleated eyes with hydroxyapatite integrated implant versus PMMA implant
INTRODUCTION This study reports our results relating to palpebral eyelid fissure and orbital measurements following evisceration with orbital implantation of hydroxyapatite integrated implant and PMMA implant. MATERIALS AND METHODS This study is a prospective study of 43 patients that underwent evisceration for different ocular affections at University Emergency Hospital Bucharest, Ophthalmol...
متن کاملIntegrated hydroxyapatite implant and non-integrated implants in enucleated Asian patients.
INTRODUCTION This study compares the outcome and complications of integrated hydroxyapatite implant and non-integrated orbital implants following enucleation in Asian patients. MATERIALS AND METHODS This is a retrospective study of enucleated patients with coralline hydroxyapatite implants versus non-integrated implants (acrylic, glass and silicone) at the Singapore National Eye Centre from J...
متن کاملEvaluation of ocular hydroxyapatite implant with Tc-99m MDP bone scan [Persian]
Static bone scan was performed in 46 patients for evaluation of ocular Hydroxyapatite Vascularization. Study Findings indicated that bone scan, with TC-99m MDP is an appropriate method for evaluation of Hydroxyapatite Vascularization and for estimating the time For peg insertion into the Hydroxyapatite implant. Our study showed proper Hydroxyapatite Vascularization when the ratio of activ...
متن کاملThe Role of Metallic Substrate of Hydroxyapatite Coated Dental Endodontic Implants in Clinical and Pathological Success
Hydroxyapatite coatings have been used on metallic substrates in a variety of applications, including modifying the surface of human implants, bone osseointegration and biological fixation. In this paper, the effects of various kinds of metallic substrate on clinical and pathological results of in vivo tests are presented. Four kinds of endodontic implants i.e, stainless steel, cobalt base all...
متن کاملThe Role of Metallic Substrate of Hydroxyapatite Coated Dental Endodontic Implants in Clinical and Pathological Success
Hydroxyapatite coatings have been used on metallic substrates in a variety of applications, including modifying the surface of human implants, bone osseointegration and biological fixation. In this paper, the effects of various kinds of metallic substrate on clinical and pathological results of in vivo tests are presented. Four kinds of endodontic implants i.e, stainless steel, cobalt base all...
متن کامل