Carbon nanotubes as adsorbent of solid-phase extraction and matrix for laser desorption/ionization mass spectrometry.
نویسندگان
چکیده
A method with carbon nanotubes functioning both as the adsorbent of solid-phase extraction (SPE) and the matrix for matrix assisted laser desorption/ionization mass spectrometry (MALDI-MS) to analyze small molecules in solution has been developed. In this method, 10 microL suspensions of carbon nanotubes in 50% (vol/vol) methanol were added to the sample solution to extract analytes onto surface of carbon nanotubes because of their dramatic hydrophobicity. Carbon nanotubes in solution are deposited onto the bottom of tube with centrifugation. After removing the supernatant fluid, carbon nanotubes are suspended again with dispersant and pipetted directly onto the sample target of the MALDI-MS to perform a mass spectrometric analysis. It was demonstrated by analysis of a variety of small molecules that the resolution of peaks and the efficiency of desorption/ionization on the carbon nanotubes are better than those on the activated carbon. It is found that with the addition of glycerol and sucrose to the dispersant, the intensity, the ratio of signal to noise (S/N), and the resolution of peaks for analytes by mass spectrometry increased greatly. Compared with the previously reported method by depositing sample solution onto thin layer of carbon nanotubes, it is observed that the detection limit for analytes can be enhanced about 10 to 100 times due to solid-phase extraction of analytes in solution by carbon nanotubes. An acceptable result of simultaneously quantitative analysis of three analytes in solution has been achieved. The application in determining drugs spiked into urine has also been realized.
منابع مشابه
A magnetite/oxidized carbon nanotube composite used as an adsorbent and a matrix of MALDI-TOF-MS for the determination of benzo[a]pyrene.
A magnetite/oxidized carbon nanotube composite, Fe(3)O(4)@SiO(2)/OCNT, was fabricated in a simple way, and it was successfully used as a magnetic solid-phase extraction sorbent and a significant matrix of the matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) for the detection of benzo[a]pyrene (BaP).
متن کاملA Miniturised Matrix Solid - Phase Dispersion Extraction Method for The Simultaneous Determination of Pyrethroid Insecticides in Biological Samples by GC-MS
A simple and effective extraction method based on matrix solid-phase dispersion (MSPD) was developed to determine thirteen pyrethroid insecticide residues in goat tissues (liver, kidney, muscle and heart) and milk using gas chromatography electron ionization mass spectrometry method (GC-MS). The samples were pre-concentrated using C18 packing material (dispersion adsorbent), followed by clean u...
متن کاملIntegration of ion-exchange chromatography fractionation with reversed-phase liquid chromatography-atmospheric pressure chemical ionization mass spectrometer and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry for isolation and identification of compounds in Psoralea corylifolia.
An approach for the separation and identification of components in a traditional Chinese medicine Psoralea corylifolia was developed. Ion-exchange chromatography (IEC) was applied for the fractionation of P. corylifolia extract, and then followed by concentration of all the fractions with rotary vacuum evaporator. Each of the enriched fractions was then further separated on an ODS column with d...
متن کاملSensitive determination of bisphenol A and bisphenol F in canned food using a solid-phase microextraction fibre coated with single-walled carbon nanotubes before GC/MS.
A reliable and sensitive method for simultaneous determination of bisphenol A (BPA) and bisphenol F (BPF) in canned food by gas chromatography-mass spectrometry (GC/MS) is described after extraction and pre-concentration by a new solid-phase microextraction (SPME) adsorbent. The potential of single-walled carbon nanotubes (SWCNTs) as SPME adsorbent for the pre-concentration of environmental con...
متن کاملDesign, Construction and Calibration of a Laser Ionization Time-of-Flight Mass Spectrometer
A time-of-flight mass spectrometer (TOF-MS) developed in our laboratory at Isfahan University of Technology is described here. The TOF-MS instrument uses laser as the ionization source which provides an opportunity to investigate the ions formed in laser ablation or desorption. The TOF-MS has an ionization chamber containing an accelerator and an ion lens to focus the ions into a one meter line...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American Society for Mass Spectrometry
دوره 16 2 شماره
صفحات -
تاریخ انتشار 2005