Evaluation of a kinetic method for simultaneous determination of conjugated and unconjugated bilirubin.

نویسندگان

  • J B Landis
  • H L Pardue
چکیده

This paper describes a fast kinetic method for the simultaneous determination of unconjugated and conjugated bilirugin in the same reaction solution. A stopped-flow mixing system with a stabilized photometer and small computer is used to mix sample and reagent rapidly and to record 250 data points during a 700-ms reaction time, and a regression program is used to resolve these kinetic data into the concentrations of unconjugated and conjugated bilirubin. Data are reported for synthetic single and two-component samples and for serum samples. Kinetic results for synthetic mixtures and serum samples are compared with results obtained by a conventional two-step procedure. Regression equations show good linearity between kinetically determined absorbance changes and concentration, good agreement between taken and found values for total, unconjugated, and conjugated bilirubin for synthetic samples in human serum albumin, and a good correlation between kinetic and equilibrium results for these species in sera. Regression slopes for kinetic vs. equilibrium assay results for total, unconjugated, and conjugated bilirubins in sera were 1.01 +/- 0.05, 1.04 +/- 0.03 and 0.91 +/- 0.04, respectively, with intercepts of 6.6,--2.7, and 3.8 micromol/liter, and standard errors of estimate of 28, 14, and 20 micromol/liter. These data reflect uncertainties in both the kinetic and equilibrium methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the Weber-Schalm method with the Ducci-Watson modification of the Malloy-Evelyn method for serum bilirubin determination.

Unconjugated bilirubin, conjugated bilirubin, and mixtures of various proportions of each were dissolved in depigmented human serum. These, together with normal and pathologic native human sera, were analyzed for conjugated, unconjugated, and total bilirubin by the Weber-Schalm method. Results were compared with the determination of “prompt direct reacting bilirubin” and of total bilirubin by t...

متن کامل

The Ektachem clinical chemistry slide for simultaneous determination of unconjugated and sugar-conjugated bilirubin.

Using dual-wavelength spectrometry, we have refined the mordant-based bilirubin slide method (Clin Chem 28:2366-2372, 1982) to co-detect unconjugated bilirubin (Bu) and its sugar conjugates (Bc) in 10 microL of serum. The assay is based on three principles: (a) mono- and diconjugated bilirubins behave spectrally like one fraction (Bc) when bound to the mordant, (b) Bu and Bc are spectrally dist...

متن کامل

Fluorescent protein-based detection of unconjugated bilirubin in newborn serum

Increased serum levels of unconjugated bilirubin are associated with the development of brain damage in newborns. In current clinical settings, there are no methods for directly determining serum levels of unconjugated bilirubin. UnaG, a fluorescent protein from Japanese eel muscle that specifically binds to unconjugated bilirubin was used in this study. Linear regression analysis was carried o...

متن کامل

Application of Differential Kinetic Method Using ANN with a New Synthetic Reagent for Simultaneous Spectrophotometric Determination of Mercury and Palladium

A new selective reagent was used for simultaneous determination of mercury and palladium in real samples with their different kinetic spectrophotometric properties. The method is based on the difference in the rate of the oxidation reaction of the recently synthesized reagent, nitro benzoyl diphenylmethylen phosphorane (N-BDMP), with Hg2+ and Pd2+. The kinetic profiles were monitored and record...

متن کامل

Spectrophotometric Simultaneous Kinetic Determination of Iodide and Iodate Using Partial Least-Squares Calibration Method in a Single Kinetic Run

A rapid, sensitive and versatile kinetic method is presented for the simultaneous spectrophotometric determination of iodide and iodate by partial least-squares regression (PLS) using original and derivate data named as absorbance and rate data. The method is based on the catalytic effect of the cited anions on the reaction rate between Ce(IV) and As(III) in 2 mol l?1 sulfuric acid medium. The ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 24 10  شماره 

صفحات  -

تاریخ انتشار 1978