Estimated collective effective dose to the population from nuclear medicine diagnostic procedures in Croatia: A comparison of 2010 and 2015

نویسندگان

  • Ivana Kralik
  • Mario Štefanić
  • Hrvoje Brkić
  • Gordan Šarić
  • Stanko Težak
  • Svjetlana Grbac Ivanković
  • Neva Griotto
  • Damir Štimac
  • Otmar Rubin
  • Tamer Salha
  • Zrinka Ivanišević
  • Slaven Jurković
  • Dario Faj
چکیده

OBJECTIVE This study presents national surveys of patient exposure from nuclear medicine (NM) diagnostic procedures in 2010 and 2015 in the Republic of Croatia. METHODS The survey was performed according to the European Commission Dose DataMed (DDM) project methodology. 28 most frequent NM diagnostic procedures were identified. Data about frequencies of procedures and average administered activities of radioisotopes used in those procedures were collected. Average administered activities were converted to effective doses according to the dose conversion coefficients. Then the collective effective dose to the population and an effective dose per capita were calculated based on the number of the most frequent NM diagnostic procedures and the average effective dose per procedure. RESULTS In 2010, 41200 NM diagnostic procedures led to 146.7 manSv collective effective dose to the population and in 2015, 42000 NM diagnostic procedures led to 146.8 manSv collective effective dose to the population. The frequencies of NM diagnostic procedures were 9.7 and 9.8 annually per 1000 population with 34.1 μSv and 34.2 μSv effective dose per capita for 2010 and 2015, respectively. The main contributors to the annual collective dose from NM in Croatia are examinations of the bone, heart, thyroid and PET/CT tumour diagnostic. Average administered activities have not changed considerably from 2010 to 2015. Nevertheless, within the frequency of some of the procedures, significant changes were found in five-year period. CONCLUSIONS Frequencies, average administered activities and collective effective dose to the population from NM diagnostic procedures in Croatia are comparable to the values reported by other European surveys. Changes were found between 2010 and 2015 and we intend to perform this study periodically to identify possible trends, but also to raise awareness about the potential dose optimization.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiation exposure from diagnostic nuclear medicine examinations in Golestan province

Introduction: The aim of present study was to estimate effective dose from most common procedures performed in nuclear medicine departments of Golestan province. Methods: Data of nuclear medicine procedures performed in 2 nuclear medicine departments in Golestan province were collected during 4 years. Effective dose, collective effective dose and effective dose per examination were calculated ...

متن کامل

Staff and patient absorbed doses due to diagnostic nuclear medicine procedures

Background: Annual patient effective dose equivalent can be considered as a quantitative physical parameter describing the activities performed in each nuclear medicine department. Annual staff dose equivalent could be also considered as a parameter describing the amount of radiation risk for performing the activities. We calculated the staff to patient dose equivalent ratio to be used as a phy...

متن کامل

Assessment of whole-body occupational radiation exposures in nuclear medicine practices of Bangladesh during 2010-2014

Introduction: Occupational exposure to ionizing radiation due to medical activities (both diagnostic and therapeutic procedures) has increased sharply in recent years. Among the occupationally exposed workers in these fields, those most affected by this increased exposure to ionizing radiation are nuclear medicine workers. In this study, annual average effective dose, annual collective effectiv...

متن کامل

Estimated collective effective dose to the population from nuclear medicine examinations in Slovenia

BACKGROUND A national survey of patient exposure from nuclear medicine diagnostic procedures was performed by Slovenian Radiation Protection Administration in order to estimate their contribution to the collective effective dose to the population of Slovenia. METHODS A set of 36 examinations with the highest contributions to the collective effective dose was identified. Data about frequencies...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017