Intrapelvic migration of a guide pin during fixation of a hip fracture: who and what is to blame?

نویسندگان

  • Fares E Sayegh
  • Dionysios Tsintzas
  • George A Kapetanos
چکیده

The authors report the case of a 61-year-old patient who underwent internal fixation with a dynamic hip screw for a stable intertrochanteric fracture of the right hip. The immediate postoperative radiograph showed complete intrapelvic migration of the threaded guide pin, which has gone unnoticed during operation. The pin was removed by laparotomy, and was found to have damaged no pelvic viscera; the patient made an uneventful recovery. The authors analyse the mechanism of such iatrogenic complications and the possible means to avoid them.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intrapelvic Protrusion of a Broken Guide Wire Fragment during Fixation of a Femoral Neck Fracture

Breakage of DHS guide wire during surgery and its migration into the pelvis through the hip joint is a rare complication and its removal can be very challenging for the surgeon. We share our experience of a similar case wherein we used an ‘iliofemoral’ approach to successfully remove the broken transfixing guidewire from the hip joint. Although iliofemoral approach is similar to the lateral win...

متن کامل

Intrapelvic Protrusion of a Broken Guide Wire Fragment during Fixation of a Femoral Neck Fracture

  During fixation of a femoral neck fracture in a 23-year-old male patient with cannulated screws, a broken guide wire fragment inadvertently advanced through the hip joint and protruded into the pelvis. A second surgical approach was needed to remove the broken fragment from the pelvis. Awareness of such a potentially devastating complication will make surgeons more cautious during implementa...

متن کامل

Migration of a Broken Steinman Pin into the Posterior Compartment of the Leg 12 Years after Total Hip Arthroplasty

This report is on a migration of a Steinman pin into the posterior com Department of the calf. It was used to fix a greater trochanteric osteotomy in a total hip arthroplasty. The puzzling note is how this metal piece passed through the anterolateral compartment of the thigh to the posterior compartment of the calf. Accord ing to our literature review, migration of fixation pins through the kne...

متن کامل

Intra-Pelvic Migration of Sliding Hip Screw During Osteosynthesis of Hip Fracture: A Rare Avoidable Intraoperative Complication

INTRODUCTION Hip fractures, which are common among old patients, are classified into two groups: intracapsular and extracapsular fractures. Extracapsular fractures can be treated with extramedullary implants [e.g. dynamic hip screw (DHS)] or intramedullary nails. Dynamic hip screw is the treatment of choice in stable pertrochanteric fractures. Intrapelvic migration of the sliding screw is a ver...

متن کامل

Intrapelvic Protrusion of a Broken Guide Wire Fragment during Fixation of a Femoral Neck Fracture.

During fixation of a femoral neck fracture in a 23-year-old male patient with cannulated screws, a broken guide wire fragment inadvertently advanced through the hip joint and protruded into the pelvis. A second surgical approach was needed to remove the broken fragment from the pelvis. Awareness of such a potentially devastating complication will make surgeons more cautious during implementatio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta orthopaedica Belgica

دوره 71 2  شماره 

صفحات  -

تاریخ انتشار 2005